4.9 After stopping the engine – Putting the engine out of
operation
Preconditions
☑ MTU Fluids and Lubricants Specifications (A001063/..) are available.
After stopping the engine
Item
Task
Coolant circuit
Drain engine coolant (→ Page 98) if:
• the engine room is not heated;
• the engine coolant is not maintained at a suitable temperature;
• the antifreeze concentration is insufficient for the engine-room tempera‐
ture;
• antifreeze concentration is 50 % and engine-room temperature is below
-40°C.
Engine/generator/pump
control
Switch OFF.
76 | Operation | MS15022/02E 2012-04