7.16 Raw Water Pump with Connections
7.16.1 Raw water pump – Relief bore check
DANGER
Components are moving or rotating.
Risk of crushing, danger of parts of the body being caught or pulled in!
• Operate the engine at low load only. Keep clear of the danger zone of the engine.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
• Wear ear protectors.
Raw water pump, relief bore
check
1.
Check relief bore for oil and raw water dis-
charge.
2.
Stop engine (→ Page 76) and disable engine
start, observe general safety instructions
“Maintenance and Repair”.
3.
Clean the relief bore with a wire if it is dirty.
• Permissible raw water discharge: up to 10
drops per hour;
• Permissible oil discharge: up to 5 drops
per hour
4.
If discharge exceeds the specified limits:
Contact Service.