150204 – Comm. Lost Mixer (TecJet)
Red alarm. Initiated by SAM.
Cause
Corrective action
No communication with mixer
(TecJet) CAN.
1. Check supply voltage.
2. Check connecting line.
150352 – SS Release Circuit Breaker
Red alarm. Initiated by SAM.
Cause
Corrective action
Circuit breaker release detected.
u
Check circuit breakers.
150358 – HI Lube Oil Level refill
Yellow alarm. Initiated by SAM.
Cause
Corrective action
Engine oil was refilled too often
within a certain time interval.
1. Check engine oil level (→ Page 167).
2. Check oil supply (→ Page 167).
150365 – SS Gas Pressure MIN
Red alarm. Initiated by SAM.
Cause
Corrective action
Minimum gas pressure applied.
1. Check initial gas pressure and gas line.
2. Check cabling.
150399 – SS Coolant too Low
Red alarm. Initiated by SAM.
Cause
Corrective action
Lack of coolant in cooling system,
feedback signal from level sensor
missing.
1. Check sensor and cabling, replace as necessary.
2. Check coolant level.
3. Pinpoint leakage.
150400 – AL Preheating Error
Yellow alarm. Initiated by SAM.
Cause
Corrective action
Preheating fault, coolant
differential pressure over engine
is below the specified value.
1. Check differential coolant pressure.
2. Check operation of coolant pumps.
150401 – HI Oil Refill
Yellow alarm. Initiated by SAM.
Cause
Corrective action
Too many pulses received for lube
oil replenishment.
1. Check engine oil level (→ Page 167).
2. Check oil supply (→ Page 167).
80 | Troubleshooting | MS150034/04E 2016-11
TIM-ID: 0000017543 - 001