112311 – HI T-Exhaust B1
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check valve drive (exhaust valves do not close).
112312 – HI T-Exhaust B2
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check valve drive (exhaust valves do not close).
112313 – HI T-Exhaust B3
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check valve drive (exhaust valves do not close).
112314 – HI T-Exhaust B4
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check valve drive (exhaust valves do not close).
112315 – HI T-Exhaust B5
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check valve drive (exhaust valves do not close).
112316 – HI T-Exhaust B6
Yellow alarm. Initiated by EMU.
Cause
Corrective action
The exhaust temperature of this
cylinder is too high as compared
with the average value.
1. Check emission values.
2. Check ignition timing (→ Page 154).
3. Check valve drive (exhaust valves do not close).
MS150034/04E 2016-11
| Troubleshooting | 63
TIM-ID: 0000017543 - 001