152028 – Open Primary, Channel 3
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coil.
152029 – Open Primary, Channel 4
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coil.
152030 – Open Primary, Channel 5
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coil.
152031 – Open Primary, Channel 6
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coil.
152032 – Open Primary, Channel 7
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coil.
152033 – Open Primary, Channel 8
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coil.
152034 – Open Primary, Channel 9
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coil.
MS150034/04E 2016-11
| Troubleshooting | 89
TIM-ID: 0000017543 - 001