![MTU 20 V 4000 M73 x Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/mtu/20-v-4000-m73-x/20-v-4000-m73-x_operating-instructions-manual_1852697065.webp)
4.12 Coupling – Disengaging from LOP
Preconditions
☑
LOCAL OPERATION illuminated pushbutton lights up brightly (local operating mode is active).
☑
Engine speed in disengagement window.
Disengaging coupling without reversing gearbox (CPP, WJ, VS)
Item
Measure
LOP
Press COUPLING OUT illuminated pushbutton (→ Page 52).
•
COUPLING OUT button flashes.
•
Coupling is disengaged.
•
After receiving the feedback signal from coupling, the COUPLING OUT
button is illuminated brightly.
Disengaging coupling with reversing gearbox (FPP, WJ)
Item
Measure
LOP
Press COUPLING NEUTRAL illuminated pushbutton (→ Page 52).
•
COUPLING NEUTRAL button flashes.
•
Gearbox is disengaged (neutral position).
•
After receiving the feedback signal from coupling, the COUPLING NEU-
TRAL button is illuminated brightly.
MS150046/02E 2013-07 | Operation | 65