506 – AL Starter Voltage too low
Yellow alarm; warning
Cause
Corrective action
The battery voltage is too low for
the starting process.
u
Check starter battery and wiring (→ Page 149).
507 – AL POM Error
Yellow alarm; warning
Cause
Corrective action
A general POM fault occurred.
u
Replace POM.
508 – AL Wrong POM-ID
Yellow alarm; warning
Cause
Corrective action
POM sends a different ID
number than expected.
u
Check POM wiring harness.
515 – AL Starter Not Engaged
Yellow alarm; warning
Cause
Corrective action
Starter on POM could not be
engaged. If the number of
admissible automatic starting
attempts is executed, the
starting sequence is terminated.
1. Repeat start.
2. Check POM, starter and wiring (→ Page 149).
519 – Oil Level Calibration Fault (Option)
Yellow alarm; warning
Cause
Corrective action
Error writing calibration value
into flash or SD of level sensor.
u
Check sensor and wiring, replace as necessary (→ Page 149).
549 – AL Voltage Interruption Detected
Yellow alarm; warning
Cause
Corrective action
The operating voltage of the
engine governor was switched of
with the engine running. This
may lead to overpressure in the
HP fuel system, which might
cause damage to the engine.
u
Instruct the operator only to disconnect the power supply when
the engine has stopped.
72 | Troubleshooting | MS15042/00E 2014-10
TIM-ID: 0000016866 - 006