8.
Tighten clamp (6) to the specified tightening torque.
Name
Size
Type
Lubricant
Value/Standard
Clamp (6)
Tightening torque
(Assembly compound
(Ultra-Therm MTU))
20 Nm
Installing containment cover
1.
Fit new seal in bellows (12), glue with 2-
component adhesive.
2.
Coat screw threads and clamping area of
clamp (11) with assembly compound prior
to installation.
Note:
Turbine housing must not damage seal dur-
ing installation.
3.
Position turbine housing (10) on bel-
lows (12).
4.
Install turbine housing (10) with clamp (11)
on bellows (12).
5.
Tighten clamp (11) with torque wrench to the specified tightening torque.
Name
Size
Type
Lubricant
Value/Standard
Clamp
Tightening torque
(Assembly compound
(Ultra-Therm MTU))
15 Nm +2 Nm
6.
Install insulation mat on bellows (12).
7.
Install protective cover (1) with washers (9) and screws (8) and tighten with torque wrench to the speci-
fied tightening torque.
Name
Size
Type
Lubricant
Value/Standard
Screw
M12
Tightening torque
(Assembly compound
(Ultra-Therm MTU))
60 Nm +6 Nm
8.
Install heat shield (2) with spacer (5), washers (3,7) and screws (4,6).
106 | Task Description | MS15042/00E 2014-10
TIM-ID: 0000013059 - 006