![MTU 16 V 4000 M63L Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/mtu/16-v-4000-m63l/16-v-4000-m63l_operating-instructions-manual_1852687126.webp)
486 – HI T-Exhaust D
ZKP-Number: 20.134.931
Limit value 1
Cause
Corrective action
Exhaust gas temperature (D-
side) too high.
1. Reduce power.
2. Contact Service.
487 – SS T-Exhaust D
ZKP-Number: 20.134.932
Limit value 2
Cause
Corrective action
Exhaust gas temperature (D-
side) too high.
1. Reduce power.
2. Contact Service.
488 – HI ETC3 Overspeed
ZKP-Number: 2.3014.931
Speed of 2nd secondary turbocharger too high (limit value 1)
Yellow alarm; warning
Cause
Corrective action
Clogged charge-air circuit or
fault in turbocharger.
u
Reduce power.
489 – SS ETC3 Overspeed
ZKP-Number: 2.3014.932
Speed of 2nd secondary turbocharger too high (limit value 2)
Red alarm; engine shutdown
Cause
Corrective action
Clogged charge-air circuit or
fault in turbocharger.
u
Reduce power.
490 – HI ETC4 Overspeed
ZKP-Number: 2.3015.931
Speed of the 3rd secondary turbocharger too high (limit value 1)
Yellow alarm; warning
Cause
Corrective action
Clogged charge-air circuit or
fault in turbocharger.
u
Reduce power.
126 | Troubleshooting | MS150067/02E 2014-04
TIM-ID: 0000045495 - 001