Coolant system (LT circuit)
Number of cylinders
12
16
Coolant temperature before mixture cooler (at engine connection:
inlet from cooling equipment (w/o antifreeze)
A
°C
40
40
Coolant antifreeze content, max.
L
%
50
50
Coolant pump: Volumetric flow
A
m³/h
21
27
Pressure in cooling system, max.
L
bar
6.0
6.0
Pressure loss over mixture cooler (at nominal flow rate 8.56)
bar
0.2
0.6
Table 10: Coolant system (LT circuit)
Coolant system (MT circuit)
Number of cylinders
12
16
Coolant temperature before mixture cooler (at engine connection:
inlet from cooling equipment (w/o antifreeze)
A
°C
-
70
Coolant antifreeze content, max.
L
%
-
50
Coolant pump: Volumetric flow
A
m³/h
-
32
Pressure in cooling system, max.
L
bar
-
6.0
Pressure loss over MT mixture cooler (at nominal flow rate 8.56)
bar
-
3.4
Table 11: Coolant system (MT circuit)
Lube oil system
Number of cylinders
12
16
Lube oil operating temperature after oil heat exchanger, from
R
°C
82
82
Lube oil operating temperature after oil heat exchanger, to
R
°C
90
90
Lube oil operating temperature after oil heat exchanger, warning
R
°C
93
93
Lube oil operating temperature after oil heat exchanger, engine
shutdown
L
°C
97
97
Lube oil pressure after oil filter
bar
5.0
5.0
Lube oil pressure after oil filter, warning
R
bar
3.5
3.5
Lube oil pressure after oil filter, shutdown
L
bar
2.5
2.5
Table 12: Lube oil system
Fuel system
Number of cylinders
12
16
Gas temperature before engine, min.
L
°C
10
10
Gas temperature before engine, max.
L
°C
50
50
Gas flow pressure before Tecjet, min.
L
mbar
30
30
Gas flow pressure before Tecjet, max.
L
mbar
120
120
Table 13: Fuel system
MS150115/00E 2013-10
| Product Summary | 25
TIM-ID: 0000045312 - 002