680 – AL ProActB Red
Red alarm.
Associated parameter 1.4550.191
Cause
Corrective action
An internal combined alarm in
throttle B was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
681 – AL NOxA Red
Red alarm.
Associated parameter 1.4560.091
Cause
Corrective action
An internal combined alarm at
NOx sensor A was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
682 – AL NOxB Red
Red alarm.
Associated parameter 1.4560.191
Cause
Corrective action
An internal combined alarm at
NOx sensor B was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
685 – AL Lube Oil Min
Red alarm.
Associated parameter 1.1480.307
Cause
Corrective action
Minimum engine oil filling level
detected.
1. Check engine oil level (→ Page 156).
2. Check replenishment system.
3. Fill oil.
686 – AL Lube Oil Max
Red alarm.
Associated parameter 1.1480.309
Cause
Corrective action
Maximum engine oil filling level
detected.
1. Check engine oil level (→ Page 156).
2. Check replenishment system.
3. Drain oil.
688 – LO Oil Refill
Yellow alarm.
Associated parameter 1.1480.301
Cause
Corrective action
No oil replenishment within a
programmable time.
u
Check oil replenishment system.
MS150115/00E 2013-10
| Troubleshooting | 127
TIM-ID: 0000044738 - 001