1.4520.234 – Error Missing Camshaft Signal
Red alarm. Initiated by IC922.
Cause
Corrective action
Missing camshaft signal for
ignition system.
u
Check sensor B1.2, check sensor clearance and cabling, replace as
necessary (→ Page 202) (→ Page 201).
1.4520.235 – Error Number of Teeth
Red alarm. Initiated by IC922.
Cause
Corrective action
Incorrect number of teeth on
timing wheel detected.
1. Check settings at ignition system.
2. Check sensor and sensor gaps (→ Page 202).
1.4520.236 – Unknown Engine Appl. Code
Red alarm. Initiated by IC922.
Cause
Corrective action
Ignition setting is not correct.
u
Check settings at ignition system.
1.4520.237 – OverSpeed Shutdown
Red alarm. Initiated by IC922.
Cause
Corrective action
Genset has exceeded admissible
speed.
u
Restart ignition.
1.4520.238 – E2PROM Checksum Error
Red alarm. Initiated by IC922.
Cause
Corrective action
Hardware not ready for operation.
1. Restart ignition.
2. Replace ignition.
1.4520.239 – Global Timing out of Range
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Specified global ignition timing is
beyond the valid range.
1. Adapt value in ECU parameter record.
2. Check settings at ignition system.
1.4520.240 – Unknown Timing or Energy Level
Red alarm. Initiated by IC922.
Cause
Corrective action
No global ignition timing and
power level received, CAN bus
connection is faulty.
u
Check cabling and setting (→ Page 201).
82 | Troubleshooting | MS150104/02E 2016-11
TIM-ID: 0000038611 - 003