
1.4540.012 – Valve Position Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Unable to set the requested flap
control.
1. Restart TecJet.
2. Check mechanical system.
3. Replace TecJet.
1.4540.013 – High Elec Temp
Red alarm. Initiated by TecJet.
Cause
Corrective action
Ambient temperature too high.
1. Restart TecJet.
2. Check room temperature and ventilation.
1.4540.014 – Elec Temp Fail High
Red alarm. Initiated by TecJet.
Cause
Corrective action
Internal temperature sensor
faulty.
1. Restart TecJet.
2. Replace TecJet.
1.4540.015 – FGT Fail High
Red alarm. Initiated by TecJet.
Cause
Corrective action
Internal gas temperature sensor
faulty.
1. Restart TecJet.
2. Replace TecJet.
1.4540.016 – Delta P Fail High
Red alarm. Initiated by TecJet.
Cause
Corrective action
Internal differential gas pressure
sensor faulty.
1. Restart TecJet.
2. Replace TecJet.
1.4540.017 – FGP Fail High
Red alarm. Initiated by TecJet.
Cause
Corrective action
Internal gas pressure sensor
faulty.
1. Restart TecJet.
2. Replace TecJet.
1.4540.018 – Coil Current Fail High
Red alarm. Initiated by TecJet.
Cause
Corrective action
Actuator current limit reached.
1. Restart TecJet.
2. Check mechanical system.
3. Replace TecJet.
MS150104/02E 2016-11
| Troubleshooting | 111
TIM-ID: 0000038611 - 003