582 – AL Emergency Stop Failed
ZKP-Number: 1.1005.006
Emergency stop command was not executed
Flashing pre-alarm and alarm
Cause
Corrective action
Engine speed does not come to
a stop within a parameterizable
time.
u
Contact Service.
586 – LO P-Oil Replenishment Pump
ZKP-Number: 2.0159.911
Oil pressure in replenishment pump too low (limit value 1)
Yellow alarm - warning
Cause
Corrective action
Insufficient oil in oil refill tank.
1. Check oil level, top up as necessary (→ Page 146).
2. Contact Service.
587 – AL Wiring PWM_CM4
ZKP-Number: 1.1041.924
Wiring problem at PWM_CM4 channel
Yellow alarm - warning
Cause
Corrective action
Cable break or short circuit on
channel PWM_CM4.
1. Check wiring to connected device or check connected device
itself (actuator/sensor) and replace if necessary (→ Page 181).
2. Contact Service.
588 – SD P-Oil Replenishment Pump
ZKP-Number: 1.0159.910
Replenishment pump oil pressure sensor signal error
Yellow alarm - warning
Cause
Corrective action
Pressure sensor faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 181).
2. Contact Service.
593 – AL T-Lube Oil, Oil Pan Too Low
ZKP-Number: 2.1090.929
Lube oil temperature in oil pan too low.
Cause
Corrective action
Preheating time not long
enough.
1. Extend preheating period.
2. Contact Service.