189 – AL CAN2 Error Passive
ZKP-Number: 2.0500.689
CAN controller 2 error
Yellow alarm - warning
Cause
Corrective action
Missing associated nodes, minor
disruptions or temporary bus
overload.
1. Check CAN bus for short circuit, rectify short circuit as required.
2. Check shielding, improve shielding if necessary.
3. Contact Service.
201 – SD T-Coolant
ZKP-Number: 1.8004.570
Coolant temperature sensor signal error
Yellow alarm - warning
Cause
Corrective action
Coolant temperature sensor
faulty.
Short circuit or wire break.
1. Check sensor and wiring (B6), replace as necessary
(→ Page 181).
2. Fault is rectified when engine is restarted (→ Page 35).
3. Contact Service.
202 – SD T-Fuel
ZKP-Number: 1.8004.572
Fuel temperature sensor signal error
Yellow alarm - warning
Cause
Corrective action
Fuel temperature sensor faulty.
Short circuit or wire break.
1. Check sensor and wiring (B33), replace as necessary
(→ Page 181).
2. Fault is rectified when engine is restarted (→ Page 35).
3. Contact Service.
203 – SD T-Charge Air
ZKP-Number: 1.8004.571
Charge-air temperature sensor signal error
Yellow alarm - warning
Cause
Corrective action
Charge air temperature sensor
faulty.
Short circuit or wire break.
1. Check sensor and wiring (B9), replace as necessary
(→ Page 181).
2. Fault is rectified when engine is restarted. (→ Page 35)
3. Contact Service.
MS150096/01E 2012-08 | Troubleshooting | 59