Alternatively: Filling with engine
coolant through filler neck
1.
Open vent points on intercooler, intermedi‐
ate cooler and distributors (arrows).
2.
Fill in coolant in expansion tank via filler
neck until coolant level at top edge of filler
neck remains constant.
3.
Check proper condition of breather valve
and clean sealing faces if required.
4.
Place breather valve onto filler neck and
close until first stop is reached.
5.
Start engine (→ Page 35).
6.
After 10 seconds of running the engine
without load, shut down the engine
(→ Page 36).
7.
Turn breather valve counterclockwise and
remove.
8.
Check charge-air coolant level
(→ Page 165) and top up if required .
a) Repeat the steps from "Start engine"
(→ Step 5) until coolant no longer needs
to be topped up.
b) Check proper condition of breather
valve and clean sealing faces if re‐
quired.
c) Set breather valve onto filler neck and
close it.
Final steps
1.
Start the engine and run it without load for some minutes.
2.
Check charge-air coolant level (→ Page 165) and top up if required.
MS150096/01E 2012-08 | Task Description | 171