341 – AL Open Load Cylinder A1
ZKP-Number: 18.004.540
Cause
Corrective action
Disruption fault in injector
cabling to cylinder A1. Result:
Misfiring
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
342 – AL Open Load Cylinder A2
ZKP-Number: 18.004.541
Cause
Corrective action
Disruption fault in injector
cabling to cylinder A2. Result:
Misfiring
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
343 – AL Open Load Cylinder A3
ZKP-Number: 18.004.542
Cause
Corrective action
Disruption fault in injector
cabling to cylinder A3. Result:
Misfiring
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
344 – AL Open Load Cylinder A4
ZKP-Number: 18.004.543
Cause
Corrective action
Disruption fault in injector
cabling to cylinder A4. Result:
Misfiring
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
345 – AL Open Load Cylinder A5
ZKP-Number: 18.004.544
Cause
Corrective action
Disruption fault in injector
cabling to cylinder A5. Result:
Misfiring
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
346 – AL Open Load Cylinder A6
ZKP-Number: 18.004.545
Cause
Corrective action
Disruption fault in injector
cabling to cylinder A6. Result:
Misfiring
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
MS150045/02E 2013-07 | Troubleshooting | 127
TIM-ID: 0000018389 - 003