MODEL RELATED DATA (basic design)
Number of cylinders
12
12
Number of cylinders
12
12
Cylinder arrangement: V angle
Degrees
(°)
90
90
Bore
mm
135
135
Stroke
mm
156
156
Cylinder displacement
Liters
2.233
2.233
Total displacement
Liters
26.80
26.80
Inlet valves per cylinder
2
2
Exhaust valves per cylinder
2
2
COMBUSTION AIR / EXHAUST GAS
Number of cylinders
12
12
Charge-air pressure before cylinder
R
bar abs
3.3
3.3
Exhaust temperature after exhaust turbocharger
R
°C
430
450
COOLANT SYSTEM (HT circuit)
Number of cylinders
12
12
Coolant temperature (at engine connection: outlet to cooling
equipment)
A
°C
100
100
Coolant temperature after engine, warning
R
°C
106
106
Coolant temperature after engine, shutdown
L
°C
108
108
Coolant antifreeze content, max.
L
%
50
50
Coolant pump: inlet pressure, max.
L
bar
1.5
1.5
Thermostat: Starts to open
R
°C
79
79
Thermostat: Fully open
R
°C
92
92
COOLANT SYSTEM (LT circuit)
Number of cylinders
12
12
Coolant antifreeze content, max.
L
%
50
50
Charge-air temperature after intercooler, max.
L
°C
95
95
Thermostat: Starts to open
R
°C
38
38
Thermostat: Fully open
R
°C
51
51
LUBE OIL SYSTEM
Number of cylinders
12
12
Lube oil operating temperature before engine, from
R
°C
80
80
Lube oil operating temperature before engine, to
R
°C
103
103
Lube oil temperature before engine, warning
R
°C
103
103
Lube oil temperature before engine, shutdown
L
°C
105
105
Lube oil pressure before engine, warning
R
bar
5.3
5.3
Lube oil pressure before engine, shutdown
L
bar
4.8
4.8
MS150111/01E 2014-05
| Technical Data | 17
TIM-ID: 0000043671 - 001