Note:
Always replace NOx sensor together with control unit.
Installing NOx sensor
Note:
1.
Install control unit.
Note:
When the sensor was subjected to shock
or impact load, it is deemed to be defective
and may not be used.
2.
Remove protective cap on thread only just
before installation.
Note:
Do not wipe off the thread lubricant applied
by the manufacturer.
3.
Coat sensor thread with specified assembly
compound as required.
4.
Screw in sensor by hand.
5.
Tighten nut (2) to specified torque using a torque wrench.
Name
Size
Type
Lubricant
Value/Standard
Nut
M20 x 1.5 Tightening torque
(Assembly compound
(Molykote P 37))
50 Nm ±10 Nm
6.
Fit male connector (1) and latch it.
114 | Task Description | MS150111/01E 2014-05
TIM-ID: 0000025205 - 009