510 – AL Override applied
ZKP-Number: 2.7002.010
No alarm, fault is entered
Cause
Corrective action
Override Acknowledged
u
Deactivate Override.
515 – Al Starter Not Engaged
ZKP-Number: 2.1090.926
Yellow alarm; warning
Cause
Corrective action
Starter on POM could not be
engaged. If the number of
admissible automatic starting
attempts is executed, the
starting sequence is terminated.
1. Repeat start.
2. Check POM, starter and wiring (→ Page 119).
519 – Oillevel Calibration Error (optional)
ZKP-Number: 1.0158.921
Yellow alarm; warning
Cause
Corrective action
Error writing calibration value
into flash or SD of level sensor.
u
Check sensor and wiring, replace as necessary (→ Page 119).
536 – AL Wiring PWM_CM1
ZKP-Number: 1.1041.921
Yellow alarm; warning
Cause
Corrective action
Wire break or short circuit on
channel PWM_CM1.
u
Check wiring to connected device or check connected device
(actuator/sensor), replace if necessary.
549 – AL Power Cut-Off detected
ZKP-Number: 2.7001.952
Yellow alarm; warning
Cause
Corrective action
The operating voltage of the
engine governor was switched of
with the engine running. This
may lead to overpressure in the
HP fuel system, which might
cause damage to the engine.
u
Instruct the operator only to disconnect the power supply when
the engine has stopped.
68 | Troubleshooting | MS15033/02E 2015-02
TIM-ID: 0000047144 - 003