4 Operation
4.1 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Startup
Item
Action
Lube oil system
Check engine oil level (→ Page 97).
Coolant circuit
Check engine coolant level (→ Page 100);
Check charge-air coolant level (→ Page 107).
Coolant circuit
Preheat engine coolant with coolant preheating unit (if fitted).
Fuel prefilter
Drain fuel prefilter (→ Page 91).
Engine control system
Switch on.
MS15033/02E 2015-02
| Operation | 27
TIM-ID: 0000032511 - 003