background image

EXAMPLE, BCD Switch Settings

NOTE:

To configure a negative setpoint value: S6 

5.

SP1 = + 7.565 V

SP2 = - 9.480 V

S1 = 5

S1 = 0

S2 = 6

S2 = 8

S3 = 5

S3 = 4

S4 = 7

S4 = 9

S5 = 0

S5 = 0

S6 = 0

S6 = 9

25

Содержание MK292

Страница 1: ...l T e m p o s o n i c s P o s i t i o n S e n s o r s MK292 Digital Output Module Users Manual 0797 550414 Revision B...

Страница 2: ...x 919 677 0200 S h i p p i n g A d d r e s s MTS SYSTEMS CORPORATION Sensors Division 3001 Sheldon Drive Cary North Carolina 27513 O f f i c e H o u r s Mon Thurs 7 30 a m to 6 30 p m EST Friday 7 30...

Страница 3: ...P Position Sensors with Start Stop Output 6 4 1 3 Temposonics L Series Position Sensors with Start Stop Output 7 4 2 System Connections 9 4 3 Functional Inputs Outputs 10 4 3 1 Error Output Loss of Fe...

Страница 4: ...4...

Страница 5: ...rs SE based Temposonics LP sensor with start stop output Temposonics II sensors with a pulse width modulated or start stop output Temposonics L Series sensors with a pulse width modulated or start sto...

Страница 6: ...mm 24 Vdc Power Suppy Required 5 Vdc Required for TTL Output Selectable BCD Binary or Gray Code Displacement Output Optional Voltage Output 0 to 10 Vdc or 10 to 0 Vdc for recording purposes only NOTE...

Страница 7: ...to 10 Vdc used for recording option board required must be specified upon initial order 12 bit resolution 5mv ripple Fully adjustable Programming Parameters Zero Resolution Stroke Length Measuring Di...

Страница 8: ...emposonics L Series 0 03 of full scale Repeatability 0 001 of full scale or 0 0001 inch 0 002 mm whichever is greater Operating Temperature Head Electronics 40 to 150 F 40 to 66 C Sensor Rod 40 to 185...

Страница 9: ...The DPM is installed in the head of the sensor s electronics enclosure When using a Temposonics sensor with a PWM output external interrogation is required to interface with the MK292 External interro...

Страница 10: ...C24 9 White Gray Stripe Yellow Interrogation Interrogation C25 10 Gray White Stripe Green Interrogation Interrogation NOTE Verify if the cable has striped or solid color leads and make connections ac...

Страница 11: ...ion Figure 4 3 RG Connector Table 4 C 2 Connections Temposonics L Series Position Sensor with MS Connector MK292 Connection Pin No Wire Color Function C32 A White DC Ground B No Connection C28 C Gray...

Страница 12: ...egral Cable MK292 Connection Wire Color Function C28 Gray Gate C27 Pink Gate C24 Yellow Interrogation C25 Green Interrogation C2 Red or Brown Power supplied by MK292 24 Vdc C32 White DC Ground Table 4...

Страница 13: ...nary or Gray Code Polarity Displacement Output Format c15 Vin Negative c15 0V Positive Displacement Output Format Output Logic c10 Vin PWM Note 3 c10 0V Start Stop PWM or Start Stop c1 or a1 c1 or a1...

Страница 14: ...ensor magnet not positioned within the active range of sensor Malfunction or failure of sensor or module Electronic interference 4 3 2 Data Ready Output Latch Pulse Pin c6 Logic HIGH Ensures that para...

Страница 15: ...art signals must be between 6 to 10 microseconds in duration and repetition period must exceed the minimum cycle time refer to pro gramming section of the manual MR Measuring Range Figure 4 9 External...

Страница 16: ...SYSTEM PARAMETERS Sensor with PWM Outputs Sensor with Start Stop Outputs NOTE Pulse Duration REC only applies to systems that are using sensors with a PWM output System parameters are set via the fro...

Страница 17: ...ive visual indication of the operating condition and programming mode of the MK292 1 RED continuous light System in operation mode 2 RED flashing light Transition to programming mode 3 GREEN continuou...

Страница 18: ...arameter is activated 3 sec Operation Mode Hold the programming switch in Position 1 until the red RUN LED is activated This indi cates that the Programming Mode has been exited and the Operation Mode...

Страница 19: ...e of circulations meaning that the interrogation and return signals can be recirculated a specific number of times This lengthens the duration of the PWM output from the sensor and the counting time o...

Страница 20: ...limeters 0 0508 Circulation Count Resolution in inches 0 002 Circulation Count Switch Setting PWM Output circulations BCD Switch Circulations 4 Circulations 16 S1 4 6 S2 0 1 S3 0 0 S4 0 0 S5 0 0 S6 0...

Страница 21: ...D begins to flash 3 sec 3 Enter the scale factor indicated on the sensor label using the BCD switches S1 S6 Example Gradient 8 94371 BCD Switch Settings S1 1 S2 7 S3 3 S4 4 S5 9 S6 8 SC I M P O R T A...

Страница 22: ...0 005 mm Note Refer to Resolution vs Circulation Chart page 16 1 Hold the programming switch in Position 2 until the RE LED begins to flash 3 sec ADJUST 2 Enter the desired resolution using BCD switc...

Страница 23: ...the ZERO LED begins to flash 3 sec SETUP The MK292 is now ready to accept the next parameter Null Adjust ZERO MR NOTE When the measuring range is set the measuring fre quency and system update time is...

Страница 24: ...sequence 3 sec SET UP 7 7 ZERO Offset As an alternative to the ZERO NULL adjust a ZERO NULL offset can be programmed within a range of 49 9999 to 49 9999 inches The value depends on the pre set reso...

Страница 25: ...ettings S1 S6 for Offset Value 1 Hold the programming switch in Position 2 to restart programming sequence 3 sec SET UP NOTE If a set value is overwritten the programming mode has to be set again by r...

Страница 26: ...Hold the programming switch in Position 1 until the RUN LED begins to flash 3 sec SETUP The Programming Mode is exited and all parameter settings are stored in an EEPROM within the MK292 module You a...

Страница 27: ...uration is defined by the zero position and measuring range of the sensor The three possible configurations are illustrated in Fig 8 2 Figure 8 2 Null Set Up 10 V 0 V No 1 Null Set Up 0 V 10 V No 2 Nu...

Страница 28: ...SP1 using the BCD switches S1 least significant bit S5 most significant bit 6 Hold the programming switch in Position 2 until SC is lit 3 seconds ZERO is also lit 7 The output value at SP1 is now sto...

Страница 29: ...EXAMPLE BCD Switch Settings NOTE To configure a negative setpoint value S6 5 SP1 7 565 V SP2 9 480 V S1 5 S1 0 S2 6 S2 8 S3 5 S3 4 S4 7 S4 9 S5 0 S5 0 S6 0 S6 9 25...

Страница 30: ...ederal Republic of Germany Phone 49 23 5195870 Fax 49 23 5156491 MTS Sensors Technology Corp Izumikan Gobancho 12 11 Gobancho Chiyoda ku Tokyo 102 Japan Phone 3 3239 3003 Fax 3 3262 7780 Temposonics i...

Отзывы: