4. Connections
4.1.1 Temposonics II Position Sensors with DPM or RPM
Table 4-A Connections - Temposonics II Position Sensor
MK292
Wire Color
Wire Color
Function
Function
Connections
Pin No.
(Striped Leads)
(Solid Leads)
w/PWM Output
w/Start/Stop Output
C32
1
White/Blue Stripe
White
DC Ground
DC Ground
C32
2
Blue/White Stripe
Brown
Frame
Frame
C28
3
White/Orange Stripe
Gray
(-) Gate Out
(-) Start/Stop Pulse
C27
4
Orange/White Stripe
Pink
(+) Gate Out
(+) Start/Stop Pulse
C30
5
White/Green Stripe
Red
+ 15 Vdc
+ 15 Vdc
C31
6
Green/White Stripe
Blue
- 15 Vdc
- 15 Vdc
No Connection
7
White/Brown Stripe
Black
Not Used
Not Used
No Connection
8
Brown/White Stripe
Violet
Not Used
Not Used
C24
9
White/Gray Stripe
Yellow
(+) Interrogation
(+) Interrogation
C25
10
Gray/White Stripe
Green
(-) Interrogation
(-) Interrogation
NOTE:
Verify if the cable has striped or solid color leads and make connections accordingly.
Figure 4-1
10 Pin 'RB' Style Connector
(Mating Connector: P/N 400755-3)
4.1.2 SE-based Temposonics LP Position Sensors with Start/Stop Output
Table 4-B Connections - SE-based Temposonics LP Position Sensor
MK292
Sensor
Connections
Pin No.
Wire Color
Function
C28
1
Blue
Gate (-)
C27
2
Green
Gate (+)
C25
3
Yellow
Interrogation (-)
C24
4
Orange
Interrogation (+)
C30
5
Red
Power, provided by MK292 (+15, ± 10%)
C32
6
Black
Ground
No Connection
7
Drain
Shield Drain Wire
No Connection
8
N/A
N/A
Figure 4-2a
Figure 4-2b
Integral Connector
Hanging Connector
Connection Type C,
Connection Type H or J,
External View
External View
1
2
3
6
5
8
4
7
1
2
3
6
5
8
4
7
1
2
3
5
7
9
4
6
8
10
6
Содержание MK292
Страница 4: ...4...