2.2 Major applications and scope of application

 

The Pulse  Oximeter  can be used  in  measuring  the pulse oxygen  saturation  and pulse rate  through 

finger. The product is suitable for being  used in family, hospital,  oxygen bar, community healthcare, 

physical care in sports (It can be used before or after doing  sports and it is not recommended to use 

the device during the process of having sport) and etc.   

The  problem  of  overrating  would  emerge  when  the  patient  is  suffering  from  toxicosis 

which  caused  by  carbon  monoxide,  the  device  is  not  recommended  to  be  used  under  this 

circumstance.

 

 

2.3 Environment requirements 

Storage Environment 

  a) Temperature:

-40℃~+60℃ 

 b

) Relative humidity :

5%~95% 

 c

) Atmospheric pressure :

500hPa~1060hPa 

 

Operating Environment 

a) Temperature:1

0℃~40℃ 

b) Relative Humidity :

30%~75% 

c

) Atmospheric pressure:

700hPa~1060hPa  

3 Principle 

Principle of the Oximeter is as follows: An experience formula of data process is established taking 

use  of  Lambert  Beer  Law  according  to  Spectrum  Absorption  Characteristics  of  Reductive 

Hemoglobin (Hb) and Oxyhemoglobin (HbO

2

) in glow & near-infrared zones. Operation principle of 

the  device  is:  Photoelectric  Oxyhemoglobin  Inspection  Technology  is  adopted  in  accordance  with 

Capacity  Pulse  Scanning  &  Recording  Technology,  so  that  two  beams  of  different  wavelength  of 

lights  can  be  focused  onto  human  nail  tip  through  perspective  clamp  finger-type  sensor.  Then 

measured signal can be obtained by a photosensitive element, information acquired through which 

will be shown on screen through treatment in electronic circuits and microprocessor. 

 

 

Figure 1. 

 

Содержание CMS-50FF

Страница 1: ...ty and performance issues and any monitoring abnormality human injury and equipment damage due to users negligence of the operation instructions The manufacturer s warranty service does not cover such...

Страница 2: ...cations 4 4 1Mainperformance 4 4 2MainParameters 4 5Installation 5 5 1Viewofthefrontpanel 5 5 2Wristbandinstallationandprobeconnection 5 5 3Accessories 6 6OperatingGuide 6 6 1Applicationmethod 6 6 2At...

Страница 3: ...attery plastic bags foams and paper boxes should follow the local laws and regulations Please check the packing before use to make sure the device and accessories are totally in accordance with the pa...

Страница 4: ...d default setting for good This function could be turned on through menu operation if you need Please check the chapter 6 1 as a reference The device may not work for all patients If you are unable to...

Страница 5: ...95 c Atmospheric pressure 500hPa 1060hPa Operating Environment a Temperature 10 40 b Relative Humidity 30 75 c Atmospheric pressure 700hPa 1060hPa 3 Principle Principle of the Oximeter is as follows A...

Страница 6: ...rs A Measurement of SpO2 Measuring range 0 100 Accuracy When the SpO2 measuring range is 70 100 the permission of absolute error is 2 Below 70 unspecified B Measurement of pulse rate Measuring range 3...

Страница 7: ...ication light When the device is in the state of battering charging the indication light appears to be orange and when the battery status is full the light turns to green 5 2 Wristband installation an...

Страница 8: ...by our company never replace it with the similar ones by other manufacturers b Put the finger into the probe c Turn on the device by long pressing the button on the panel d Do not shake the finger and...

Страница 9: ...order to enter the clock interface and the device would return to the measuring interface by Press the button for about 10 seconds again D Pause alarm a Alarm including the alarm of measure data s goi...

Страница 10: ...LM HI SpO2 low limit SpO2 ALM LO Pulse rate high limit PR ALM HI Pulse rate low limit PR ALM LO Press the button and hold to adjust the selected limit to the desired higher value and release the butto...

Страница 11: ...lock Setting Menu a When entering the clock setting menu the menu choice bar would be on the item of set time and the state would always be no whenever it enters the clock setting menu on the purpose...

Страница 12: ...Figure 8 SpO2 program Figure 9 SpO2 Review program If the users choose to turn on the synchronizing display function on computer it would probably take several seconds for the data to appear on the co...

Страница 13: ...d to your computer c In the state of storing it is not applicable for the users to upload the stored date to computer d When the upload of stored data is finished the menu choice bar will move to Exit...

Страница 14: ...digo blue or carbon monoxide hemoglobin COHb or methionine Me Hb or thiosalicylic hemoglobin and some with icterus problem the SpO2 determination by this monitor may be inaccurate C The drugs like dop...

Страница 15: ...The batteries are drained or almost drained 2 The device s malfunction 1 Please recharge the battery 2 Please contact the local service center The display is off suddenly 1 The device s malfunction 2...

Страница 16: ...Function Specification Information Display Mode The Pulse Oxygen Saturation SpO2 2 digit digital OLED display Pulse Rate PR 3 digit digital OLED display Pulse Intensity bar graph bar graph OLED displ...

Страница 17: ...ent Voltage 3 7 rechargeable lithium battery 1 Battery working life Charge and discharge no less than 500 times Power Adapter Input Voltage 100 to 240 VAC 50 60 Hz Output voltage 5 VDC Output current...

Страница 18: ...Medical Test Supply CMS 50FF...

Отзывы: