As to the fingers which are too thin or too cold, it would probably affect the normal measure 

of  the  patients'  SpO

2

  and  pulse  rate,  please  clip  the  thick  finger  such as  thumb  and  middle  finger 

deeply enough into the probe. 

 

The pulse oximeter can be used to adult or infant. Whether the device is used to adult or infant, 

it depends on the probe selected.   

 

Whether the device is used to adult or infant, it depends on the probe selected.   

 

The update period of data is less than 5 seconds, which is changeable according to different 

individual pulse rate. 

 

Please  read the  measured  value  when  the  waveform  on  screen  is  equably  and steady-going,       

this measured value is optimal value. And the waveform at the moment is the standard one. 

 

If some abnormal conditions appear on the screen during test process, pull out the finger and 

reinsert to restore normal use. 

 

The device has normal useful life for three years since the first electrified use.   

 

This device has the function of alarming; users can check on this function according to chapter 

6.1 as a reference. 

 

The device has the function of limits alarming, when the measured data is beyond the highest 

or  lowest  limit,  the  device  would  start  alarming  automatically  on  the  premise  of  the  alarming 

function is on. 

 

The device has the function of alarming, this function can either be paused, or closed (default 

setting) for good. This function could be turned on through menu operation if you need. Please check 

the chapter 6.1 as a reference. 

 

The  device  may  not  work  for  all  patients.  If  you  are  unable  to  achieve  stable  readings, 

discontinue use. 

2 Overview 

 

The pulse oxygen saturation is the percentage of HbO

2

 

in the total Hb in the blood, so-called the O

2

 

concentration in the blood. It is an important bio-parameter for the respiration. A number of diseases 

relating to respiratory system may cause the decrease of SpO

2

 in the blood, furthermore, some other 

causes such as the  malfunction  of human body's  self-adjustment,  damages during  surgery,  and  the 

injuries  caused  by  some  medical  checkup  would  also  lead  to  the  difficulty  of  oxygen  supply  in 

human  body,  and  the  corresponding  symptoms  would  appear  as  a  consequence,  such  as  vertigo, 

impotence,  vomit  etc.  Serious  symptoms  might  bring  danger  to  human's  life.  Therefore,  prompt 

information of patients' SpO

2

 is of great help for the doctor to discover the potential danger, and is of 

great importance in the clinical medical field.   

The  Pulse  Oximeter  features  in  small  volume,  low  power  consumption,  convenient  operation  and 

being portable. It is only necessary for patients to put one of his fingers into a probe for diagnosis, and 

a  display  screen  will  directly  show  the  measured  value  of  pulse  oxygen  saturation  with  the  high 

veracity and repetition.   

 

2.1 Features 

 

A.   

Operation of the product is simple and convenient.   

B.

    The product is small in volume, light in weight and convenient in carrying.   

C. 

  Low power consumption   

Содержание CMS-50FF

Страница 1: ...ty and performance issues and any monitoring abnormality human injury and equipment damage due to users negligence of the operation instructions The manufacturer s warranty service does not cover such...

Страница 2: ...cations 4 4 1Mainperformance 4 4 2MainParameters 4 5Installation 5 5 1Viewofthefrontpanel 5 5 2Wristbandinstallationandprobeconnection 5 5 3Accessories 6 6OperatingGuide 6 6 1Applicationmethod 6 6 2At...

Страница 3: ...attery plastic bags foams and paper boxes should follow the local laws and regulations Please check the packing before use to make sure the device and accessories are totally in accordance with the pa...

Страница 4: ...d default setting for good This function could be turned on through menu operation if you need Please check the chapter 6 1 as a reference The device may not work for all patients If you are unable to...

Страница 5: ...95 c Atmospheric pressure 500hPa 1060hPa Operating Environment a Temperature 10 40 b Relative Humidity 30 75 c Atmospheric pressure 700hPa 1060hPa 3 Principle Principle of the Oximeter is as follows A...

Страница 6: ...rs A Measurement of SpO2 Measuring range 0 100 Accuracy When the SpO2 measuring range is 70 100 the permission of absolute error is 2 Below 70 unspecified B Measurement of pulse rate Measuring range 3...

Страница 7: ...ication light When the device is in the state of battering charging the indication light appears to be orange and when the battery status is full the light turns to green 5 2 Wristband installation an...

Страница 8: ...by our company never replace it with the similar ones by other manufacturers b Put the finger into the probe c Turn on the device by long pressing the button on the panel d Do not shake the finger and...

Страница 9: ...order to enter the clock interface and the device would return to the measuring interface by Press the button for about 10 seconds again D Pause alarm a Alarm including the alarm of measure data s goi...

Страница 10: ...LM HI SpO2 low limit SpO2 ALM LO Pulse rate high limit PR ALM HI Pulse rate low limit PR ALM LO Press the button and hold to adjust the selected limit to the desired higher value and release the butto...

Страница 11: ...lock Setting Menu a When entering the clock setting menu the menu choice bar would be on the item of set time and the state would always be no whenever it enters the clock setting menu on the purpose...

Страница 12: ...Figure 8 SpO2 program Figure 9 SpO2 Review program If the users choose to turn on the synchronizing display function on computer it would probably take several seconds for the data to appear on the co...

Страница 13: ...d to your computer c In the state of storing it is not applicable for the users to upload the stored date to computer d When the upload of stored data is finished the menu choice bar will move to Exit...

Страница 14: ...digo blue or carbon monoxide hemoglobin COHb or methionine Me Hb or thiosalicylic hemoglobin and some with icterus problem the SpO2 determination by this monitor may be inaccurate C The drugs like dop...

Страница 15: ...The batteries are drained or almost drained 2 The device s malfunction 1 Please recharge the battery 2 Please contact the local service center The display is off suddenly 1 The device s malfunction 2...

Страница 16: ...Function Specification Information Display Mode The Pulse Oxygen Saturation SpO2 2 digit digital OLED display Pulse Rate PR 3 digit digital OLED display Pulse Intensity bar graph bar graph OLED displ...

Страница 17: ...ent Voltage 3 7 rechargeable lithium battery 1 Battery working life Charge and discharge no less than 500 times Power Adapter Input Voltage 100 to 240 VAC 50 60 Hz Output voltage 5 VDC Output current...

Страница 18: ...Medical Test Supply CMS 50FF...

Отзывы: