Technology Manual – Instantaneous Gas Water Heater 5L/6L CF
- 13 -
FIXATION OF HEATER
1) The place and the size of water inlet, water outlet and gas inlet to see the heater.
2) Drill two holes (
Φ
8, depth 50mm)in the wall according to the size of the A, and insert two
Φ
8
plastic expansion bolt into the holes.
3) Hang on the heater to score the point below the heater (B), take down the heater. Drill two holes
Φ
6, depth 40mm, insert two
Φ
6 plastic expansions bushing into the holes.
4) Hang on the heater and screw down the
Φ
8 nut above the heater and the
Φ
6 screw below the
heater.
5) Check that the heater is fixed in a right position without any inclination, vertically and horizontally.
MM
A
160
B
160
C
450
D
300
E
440
F
125