Technology Manual – Instantaneous Gas Water Heater 5L/6L CF
- 10 -
INSTALL PLACE REQUIREMENT
Installation should be conducted by certificated professionals.
1) Preparation before installation:
z
Make sure of accordance of all the accessories with the provisions in the instruction
z
Make sure of accordance of the gas to be applied with the requirement of nameplate
2) Installation
place
requirement
z
The heater should be installed in a well ventilated place or room, such as: kitchen, a
room not used for living, well ventilated corridor
z
The height from floor to ceiling should be more than 2.4m
z
The air inlet port should be built up directly through to the outdoor air, and its section
area not less than 0.02m
2
, but must be more than that of exhaust tube. The height from
the floor should not be less than 30mm.
z
Mind: It is strictly prohibited to install the heater at the places stated below:
A. Bedroom, dressing-room, dark room, bathroom, living room
B. Basement, electrical appliance and meter room, boiler room
C. Sites where flammables, explosives or erosive material are located nearby.
D. Sites where significant vibration occurs or any other factors that may affect the
heater’s normal operation.
E. Kitchen
cabinet
F. Somewhere nearby stairs or exit.