7.2.4
Verify that the new sensor is listed in the I/O Configuration tree.
The MTS EtherNet/IP
TM
sensor is now added to the network and
connected, ready to use.
NOTICE
If the sensor is disconnected, a yellow warning sign (shown below)
will appear over the module icon.
Fig. 64: New module on the network
Fig. 65: Add a new module to the RSLogix 5000 IO tree
Fig. 66: Add a new Generic module
Before you begin, you will need the sensors permanent IP address you
recorded in from section 6.1.3.
7.3.1
Open the
RSLogix 500
software interface.
7.3.2
Open the controllers’ directory tree. Click
I/O configuration
,
then right click your
network
. Select “
New Module
”. The
“Select Module” window opens.
7.3.3
In the “Select Module” window, select “Generic Ethernet
Module” and press “
OK
”. The “New Module” window opens.
7.3 Add sensor to I/O configuration w/o using EDS file