![MTS Sensors Level Plus LP Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/mts-sensors/level-plus-lp-series/level-plus-lp-series_interface-manual_1852490023.webp)
23
Note:
Volumetric modes 6C MOD and CUST TAB are not intended for
custody transfer applications since they do not follow API standard
2540 exactly. The software for 6C MOD incorporates a moveable
temperature reference and allows for a wider range of TEC values.
Modbus Interface Manual
LP Series
Valid temperature range
Valid TEC ranges
0 to +300.0 °F
0 to 40.0 °API
0 to +250.0 °F
40.1 to 50.0 °API
0 to +200.0 °F
50.1 to 85.0 °API
Valid temperature range
Valid TEC ranges
0 to +300.0 °F
270.0 to 510.0 * 10E-6/ °F
0 to +250.0 °F
510.5 to 530.0 * 10E-6/ °F
0 to +200.0 °F
530.5 to 930.0 * 10E-6/ °F
Valid temperature range
Valid TEC ranges
0 to +300.0 °F
100.0 to 999.0 * 10E-6/ °F
Table 3: 6B light oils
Table 4: 6C chemicals
Table 5: 6C MOD
*For the transition group, A(T) = [K1 + K0 (DEN (T) x DEN (T))]
**TEC is the thermal expansion coefficient of the product being measured
*For the transition group, A(T) = [K1 + K0 (DEN (T) x DEN (T)) measured