UNIVERSAL OIL HEATER 

TYPE MTM 52 kW 

 

ORIGINAL MANUAL 

 

 

   

 

 

 

 

 

 

v. 08/2015 

 

Содержание 52

Страница 1: ...UNIVERSAL OIL HEATER TYPE MTM 52 kW ORIGINAL MANUAL v 08 2015 ...

Страница 2: ...n Risk assessment and risk reduction EN ISO 13732 1 2008 Ergonomics of the thermal environment Methods for the assessment of human responses to contact with surfaces Part 1 Hot surfaces EN ISO 13857 2008 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs EN ISO 14159 2008 Safety of machinery Hygiene requirements for the design of machinery EN 60335 ...

Страница 3: ...ical contamination 3 Use environmental conditions The universal oil heater type MTM 52 must be used in the following conditions temperature relative humidity pressure IP protection level against environmental impact good ventilation of the heated room device noise 4 Safety aspects It is inadmissible to use fuels other than specified in point 1 of the Original Manual In particular it is forbidden t...

Страница 4: ...peration until the furnace has cooled down to the temperature below 35 C The other bimetallic sensor is located on the heat exchanger as well and its threshold temperature equals 90 C Its contact opening resulting from exceeding the threshold temperature causes the stove to immediately enter the Overheating phase see point 8 in this Manual The heater is also equipped with a weight sensor located u...

Страница 5: ...amber during heater operation to provide optimal draught install an at least 5 metre long smooth vertical stack pipe resistant to high temperature not aluminium check the leaktightness of all stack connections tighten them with insulating tape if necessary make sure that the combustion bowl is located in the combustion chamber centrally place the deflector inside the combustion chamber according t...

Страница 6: ...f the pipe runs through a wall or a window the maximal bend angle equals 45 and the minimal stack height should be increased to 6 meters the already existing ventilation ducts must not be used to build the stack system CAUTION IF AN ADDITIONAL HEAT EXCHANGER IS INSTALLED ON THE STACK SYSTEM e g EXHAUST FUMES ECONOMISER IT IS ADVISABLE TO CLEAN THE EXCHANGER AT LEAST ONCE A MONTH depending on the f...

Страница 7: ...he standby phase Stop no heat is generated the fan and the pump do not operate The diode STANDBY lights on the controller in this time Pressing the button Start causes the diode OPERATION to light up and the stove to go into the firing up phase During this phase the diode OPERATION is blinking When the furnace has heated up to ca 40 C contact shorting of the control thermostat located next to the ...

Страница 8: ...peration wait until the stove has cooled down i e the fan has switched off and press the button on the casing of the bimetallic sensor Then press the Stop button which will cause the heating diode and the sound signal to turn off The stove may now be switched on again The overflow signal is generated by the micro switch located under the overflow tank The contact opening signals that the tank has ...

Страница 9: ...ether the feeding pipe burner of the device is maximally pushed to the device housing if not push it Insert the power plug in the power socket 230V 50Hz the diode STANDBY lights up Draw the top part of the heater housing aside and remove the combustion chamber cover Then take the deflector out if necessary thoroughly clean the combustion bowl the base which it is placed on and the entire combustio...

Страница 10: ...ration of the device clean the furnace bowl and other combustion chamber elements everyday before firing up The maximal device operation time without cleaning the bowl is about 7 12 hours depending on the employed oil intended for combustion check the passability of the overflow pipe the pipe in the lower part of the combustion chamber directly over the overflow bowl clean if necessary clean the c...

Страница 11: ... too thick or too cold Dilute with diesel oil Check the pump control thermostat and replace it if needed Check the motor and see if the pump is not soiled on the inside Check STB and overflow protection 5 The fuel ducts is obstructed oil returns to the tank through the primary duct Clean the fuel duct and replace it if needed 6 The pump operation control thermostat has not reached proper temperatu...