Alarm Port
DB-9 Female (Looking at Rear of Quad)
1. Alarm Out COM
2. Alarm Out NO
3. Alarm Out NC
4. GND
5. Alarm Control
6. Ch1 Alarm Input
7. Ch2 Alarm Input
8. Ch3 Alarm Input
9. Ch4 Alarm Input
Shield - GND
Note: The Alarm input 1 to 4 and clear input are pulled high
internally. Connect the external alarm devices to these
pins.The quad will detect the type of external alarm equipment
automatically in power-on initialization but can be changed in
programming also.
The internal relay was set to NC position normally for the
Alarm output. So pin 1 and 3 will short normally, and will be
opened when an event was occurred.
Pin 2 will be open normally, and will be closed when an alarm
occurs.
Warning: The rating of the internal relay is:
AC 120V @ 1A or DC 30V @ 1A. The user must take care in
not overloading this relay for safety reasons.
15