DCQ-2000
Digital Color
Quad Processor
Operation Manual
15/02/2002
Страница 1: ...DCQ 2000 Digital Color Quad Processor Operation Manual 15 02 2002 ...
Страница 2: ...e Quad Mode 9 Single Camera Mode 9 Sequential Mode 9 VCR Playback Mode 9 2x Zooming and Freezing 9 Live Zoom Mode 10 Setup Menu 1st Page Menu Screen 11 2nd Page Menu Screen 12 3rd Page Menu Screen 13 4th Page Menu Screen 14 Alarms Alarm Pin Outs 15 Alarm Mode Operation 16 Alarm Inputs 16 Alarm Control 16 Alarm Output 17 PAL NTSC 17 Specifications 18 Warranty Information 19 ...
Страница 3: ...ogrammable Alarm Output Relay NO NC Contacts with Common Audible Buzzer Alarm 99 Alarm Event Log Memory Independent Picture Controls for each Camera Brightness Contrast Tint Color 12VDC Power Input Compact Metal Case Video Loss Detection 6 Character Camera Title Time Date On Screen Multi Format Date 24 Hr Time Format Internal Clock backup in case of power outages Non Volatile Memory for Program Se...
Страница 4: ...sy user configuration of the all setups including programming the Time and Date Each camera can have an individual title or label to identify it upon viewing the monitor or playback With the built in Time Date generator the DCQ 2000 can work with standard VCRs that do not include this feature There are separate VCR input and output connectors so playback can be done through the quad itself Upon vi...
Страница 5: ...ry location Dampness or moisture will be damage the internal components 7 Do not block ventilation openings on unit 8 Never insert any objects into unit this could result in fire or electric shock Never spill any liquid onto or into the unit 9 If an outdoor cable is connected to this unit be sure the cable is grounded well 10 For added protection of this unit during a lightning or electrical storm...
Страница 6: ... Menu VCR Mode 4 Select Item in menu 2 Quad Mode Sequential 5 Change Status in menu 3 Camera Select Rear Panel 1 2 3 4 5 6 1 Video In 1 4 4 Alarm Port 2 Monitor Out 5 Power In 12VDC 3 VCR Input Playback In 6 VCR Output Record Out 6 ...
Страница 7: ... the output of the VCR to be playbacked back or zoom on the Quad However when the Quad is in this playback mode it does not send the Quad picture out to the VCR In other words the Quad is a Simplex unit it can either display the Quad image or do Playback from a VCR but can not do both at the same time 4 Connect the Monitor Out to the Video In of the monitor or A V connectors on your TV 5 Connect t...
Страница 8: ...Typical Installation 12VDC Power Alarms Monitor Live Zoom Mode 8 Color Cameras VCR Monitor Color Camera ...
Страница 9: ...f the camera selected In this mode the monitor output port will output the camera that the user has selected Press the Quad key again to go back to the quad display Sequential Camera Mode Press the Seq key and hold for 1 second to start the auto matic camera sequencing If any camera input has a video loss or no connection the quad will automatically skip this camera in the sequencing VCR Playback ...
Страница 10: ...the end of the recorded section prior to Playback and press the record button to continue with normal recording Live Zoom Mode The DCQ 2000 can be used for live zoom of any video source However when doing this you must connect your live video source directly to the VCR Input on the Quad Then you will enter the VCR Playback mode without the VCR being con nected The live image from your camera or ot...
Страница 11: ...s 1st OSD Menu Auto Reset Every time there has been an Alarm or V Loss event the DCQ 2000 will trigger an internal timer When the timer reaches the value that the user sets this unit will clear the event automatically Unit Second The user can clear the event by pressing any key Alarm Sens The alarm event will not occur unless the Alarm trigger is longer than what is set here by the user Unit milli...
Страница 12: ...hile in the sequencing mode Unit second 2nd OSD Menu Ch This selects the input channel or camera number that is to be programmed Title This is the six character title that can be programmed for each camera input Interval This is the dwell time for each camera while in the sequencing mode Color The color killer default is Auto to adjust for color or B W cameras If the video signal of the selected c...
Страница 13: ...contrast of the selected camera Sat This adjusts the color saturation or amount of color of the selected camera Hue This adjusts the hue or tint of the selected camera Alarm There are three parts to this item 1st selection is to set the type of external alarm equip ment This is NO Normally Open or NC Normally Closed types of contacts 2nd is to select the status detected by this unit in the power o...
Страница 14: ...le or disable the unit to check for video loss for all cameras 4th OSD Menu P The selects the page number of the alarm record event log There are 11 pages with 9 records in each page with a total of 99 records maximum in the alarm log There are 4 parts to each record Alarm or VLoss Camera Number Date Time 14 ...
Страница 15: ...ese pins The quad will detect the type of external alarm equipment automatically in power on initialization but can be changed in programming also The internal relay was set to NC position normally for the Alarm output So pin 1 and 3 will short normally and will be opened when an event was occurred Pin 2 will be open normally and will be closed when an alarm occurs Warning The rating of the intern...
Страница 16: ...conditions are cleared Alarm Control The Alarm Control connection to the DB 9 connector can be used to lock the alarming camera to full screen After any alarm input has been activated and that camera is full screen connecting the Alarm Control signal to ground will lock that camera to the homing mode This will be the only camera you will see If another alarm is activated this alarm camera will hom...
Страница 17: ...is a Form C contact There is a NO Normally Open a NC Normally Closed and a Common output The rating of the internal relay is AC 120V 240V 1A or DC 30V 1A PAL NTSC The DCQ 2000 is factory configured for the PAL format However the DCQ 2000 can operate in the NTSC format This requires the changing of the internal jumpers only Please refer to an AVE approved service technician for converting the DCQ 2...
Страница 18: ...75 ohm terminated VCR Output BNC Composite Video 1 V P P into 75 ohm terminated load Monitor Output BNC Composite Video 1 V P P into 75 ohm terminated load Alarm Input DB 9 F Hi Z Impedance NO or NC programmable 1 per camera Alarm Output DB 9 F Relay Form C Contact NO NC Common AC 120V 1A DC 30V 1A Operation Temperature 5 degrees to 45 degrees Celsius Relative Humdity 5 to 85 Non Condensing Weight...
Страница 19: ...g from loss of use loss of time or inconvenience costs of temporary replacement units or spares property damage caused by this unit or its failure to work or any other incidental or consequential damages Hostile operating environments In transit damage claims improper handling by carrier of post offices Products or parts thereof which have had serial numbers removed altered or defaced Damage defec...
Страница 20: ...Multiplexer Technology Inc 9070 Royal Monarch Ct Las Vegas Nevada 89147 Telepone 702 341 0333 Fax 702 341 0334 Email MTI multiplexertechnology com Website www multiplexertechnology com ...