background image

Premier SD60E Diesel Engine

Conventional DC Operation

Your MTH locomotive will operate on conventional DC track voltage also. However, 
functions such as sounding the horn, ringing the bell and the PFA sounds cannot be 
initiated in conventional DC.  Only the engine sounds, smoke, squealing brakes and idle 
sounds will function. 

Operation of  your MTH Proto-Sound® 3.0 engine in conventional DC is very similar 
to operating a conventional AC engine. As you increase track voltage, engine speed 
increases.

As the track voltage is decreased, engine speed is decreased. When track voltage polarity 
is reversed using the polarity or direction switch on the power pack, the engine will run 
in the opposite direction. The electronics in your MTH Proto-Sound® 3.0 locomotive 
are designed to slowly change direction without a need to change the throttle, if  you so 
desire.

Just change the polarity switch on your DC power pack and the engine will gradually 
come to a stop and then automatically begin traveling in the opposite direction. The 
speed will build up to the same speed that the engine was going in the previous 
direction. When power is first applied to the locomotive, the engine’s sounds will start 
up when the track voltage reaches about 8 VDC.  To get your locomotive moving, after 
the startup sounds have finished and the locomotive is idling, slowly increase the track 
voltage until the locomotive is traveling at the desired speed.

NOTE

: If  you apply more than 9.0VDC to the engine at start-up the engine will not 

move. This is normal. We refer to this as “Anti-Jackrabbit” and this feature prevents 
your model from taking off  at high track voltages. Simply lower the track voltage down 
below 9.0VDC and then back up to get your engine moving. This applies only when you 
start up your engine.

DCS - Digital Command System

While the acronyms are close, this is where the similarity ends between DCC and DCS.  
Yes they are both digital control systems. However, M.T.H. DCS is not DCC. There are 
several proprietary versions of  DCC on the market, but DCS is not one of  them. 
M.T.H.'s DCS System is a proven technology in the O Gauge, One Gauge, and HO 
Gauge markets. First the power signal in DCS is not the command signal. Next DCS 
employs a fully functional bi-directional communication scheme opening a vast range of  
advanced features and yet so simple and intuitive that you can enjoy them. No 
programming tracks, bits and bytes, or conversion of  binary to hexadecimal numbers 
here. To add an engine in DCS, press “ADD ENGINE”. After that, if  you want to start 
your engine just press “START UP” or to turn the smoke unit on or off, just press 
“SMOKE”. No combination of  letters or numbers to remember. 

Additional details can be found in the DCS manual that accompanies your DCS system 
or on the MTH Web site, www.mthtrains.com. With DCS, you can have a whole fleet of  
MTH PS 3.0 engines on the rails and they will remain shut down until you command 
them to start up.

14

Содержание Premier SD60E

Страница 1: ...alTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 46 47 for a complete list of compatible transformers power packs and wiring instructi...

Страница 2: ...brication 3 Priming the Smoke Unit 3 Configuring Locomotive for 2 Rail or 3 Rail Operation 4 PS 3 0 Enhancements 5 Conventional AC DC Start up Shut down 5 DCS DCC Switch 6 Programming Track for DCC op...

Страница 3: ...ons from the M T H Parts Department Lubrication You should lubricate the engine to prevent it from squeaking and to prevent excessive wear Use light household oil and follow the lubrication points mar...

Страница 4: ...rack To configure the locomotive for 2 Rail track operation please do the following 1 Remove the center rail pickup roller assemblies as seen in the figure below 2 Change the power input from 3 Rail t...

Страница 5: ...pacitors to hold the engine board alive for a short time when you shut off or interrupt track power Because of this when you first apply track power to your PS3 0 equipped O Gauge engine you will noti...

Страница 6: ...re available on our website MTH will make announcements as they are available Not all updates will apply to all engines NOTE Requires a TIU w version 4 20 or later firmware and requires Consumer Loade...

Страница 7: ...to 0 volts and back again will change the sequence to the forward state Then increasing the throttle will begin to move the engine forward and speed will increase as the throttle is advanced If there...

Страница 8: ...bell firmly press and release the Bell button To turn the bell off press and release the Bell button again The bell will continue to ring from the time you turn it on until you press and release the...

Страница 9: ...e control completely counterclockwise will turn of all of the engine sounds and announcements Feature to Be Activated Button Code Marker Lights 1 Bell 1 Horn Whistles PFA Passenger Freight Announcemen...

Страница 10: ...unit is temporarily disabled so that the train will not move as you use the Direction button to trigger the sounds Proto Sound 3 0 has disabled operator control over the Horn and Bell buttons until th...

Страница 11: ...conclusion of the PFA the engine will depart in the next direction of travel as opposed to the direction it was traveling before entering Neutral Proto Coupler Operation This locomotive is equipped wi...

Страница 12: ...d control on and off put the engine in neutral then quickly tap the transformer s Horn button one time then quickly tap the Bell button two times allowing approximately second to lapse between each qu...

Страница 13: ...button allowing approximately second to lapse between each quick button press Two horn blasts will indicate that the engine has made the change Reset Two Horn Blasts indicates change is made Repeat t...

Страница 14: ...age until the locomotive is traveling at the desired speed NOTE If you apply more than 9 0VDC to the engine at start up the engine will not move This is normal We refer to this as Anti Jackrabbit and...

Страница 15: ...have a slightly different F Function list This depends upon whether it s steam diesel or electric and whether it has smoke or not Please refer to the table of Default CV Values for your particular eng...

Страница 16: ...sets The bell will then begin ringing 2 Slowly reduce the throttle until the train stops at the desired location and speed reaches zero Press the F4 button twice toggle F4 on then off again and the be...

Страница 17: ...y controlled Proto Couplers They can be fired using your DCC handheld F7 Front Coupler Pressing F7 twice toggling on then off will fire your Front Coupler F8 Rear Coupler Pressing F8 twice toggling on...

Страница 18: ...Extended Start Up If your engine is shut down or you ve just applied DCC power pressing F17 twice toggling it on then off will start the Extended Start Up sounds This is very similar to F3 except you...

Страница 19: ...le it Then when you move the engine it will play the Coupler Slack sound The second way is to simply force the sound while the engine is moving To do this simply press F22 twice toggling it on then of...

Страница 20: ...Coupler F9 Forward Signal F10 Reverse Signal F11 Grade Crossing F12 Smoke On Off F13 Smoke Volume F14 Idle Sequence 3 F15 Idle Sequence 2 F16 Idle Sequence 1 F17 Extended Start Up F18 Extended Shut D...

Страница 21: ...ressing 4 Once you hit Enter the engine will give you a two whistle horn blast response 5 Call up the engine on its new address and away you go NOTE If you have elected to use PoM and did not start up...

Страница 22: ...please wait a minimum of 5 seconds after removing power to insure the settings are stored in the engines memory Reapplying power in less than 5 seconds may result in losing the setting changes If all...

Страница 23: ...e engine s address to 55 you are just telling the DCC system to start talking to engine address 55 You will want to make sure that no other M T H engines are on the rails or any other manufacturer s e...

Страница 24: ...Acceleration Rate CV24 Consist Deceleration Adjustment CV25 Speed Table Select CV29 Decoder Configuration CV49 Short Address controllers that prohibit PoM CV50 Extended Addr High Byte controllers that...

Страница 25: ...28 Reverse Trim User ID 1 User ID 2 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155...

Страница 26: ...ly in the engine SOUNDS Bell 1 Brake Sounds 2 Cab Chatter 3 Clickety Clack 4 Coupler Close 5 Coupler Slack 6 Drift Chuff 7 Engine Sounds 8 Forward Signal 9 Grade Crossing Signal 10 Horn 11 Idle Sequen...

Страница 27: ...8 on your DCC controller The engine will give you a two horn blast indication Note You ve also left an empty location where PFA used to be F4 5 Now you can fill that location with whichever CV you d l...

Страница 28: ...nored once the consist is removed CV19 set to 0 Setting the MSB Bit 7 of CV19 tells the engine that it is facing reverse in the consist Setting CV21 and CV22 determine which F Functions the consist re...

Страница 29: ...e F0 is deactivated at the Front engine s address Most systems have a light bulb icon to indicate whether F0 is active or not Ensure that it is OFF 5 Call up the Rear engine on your DCC handheld addre...

Страница 30: ...CV21 for a Consist CV21 allows you to set which F Functions you want the consist address to control For example you will likely want all of your MTH consist engines to respond to Start Up Shut Down F3...

Страница 31: ...garding CV22 Programming Track Your MTH Proto Sound 3 0 equipped locomotive does not program well on Programming tracks due to the inclusion of super capacitors utilized in the locomotive s electronic...

Страница 32: ...r example CV29 you would simply add the additional bits you enabled to the existing value to obtain the new CV value For example if you had a consist address CV19 set to 5 and you wanted to alter this...

Страница 33: ...only a drop or two on each pivot point The locomotive s internal gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes...

Страница 34: ...lied with a cotton swab To clean the track use RailKing Track Cleaning Fluid or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag fre...

Страница 35: ...ou may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you will need to remove and reinstall the tir...

Страница 36: ...ut After removing the engine from storage add another 25 drops of fluid letting the wick soak up the fluid for 15 minutes prior to operation Smoke Unit Cover Wick in Poor Condition Wick in Good Condit...

Страница 37: ...lting in extremely long life compared to the incandescent bulbs The LEDs are not user serviceable If you experience poor or no smoke output when the smoke unit is on and has fluid check the wick to se...

Страница 38: ...sending enough power to the track to power the engine Rotate throttle clockwise to increase track power Coupler Solution When I try to fire the coupler PFA starts The Proto Coupler won t let the engin...

Страница 39: ...gine doesn t go into reverse When the PFA enters its last sequence the bell automatically comes on When PFA is enabled pressing the whistle and bell has no effect I push the direction button but the n...

Страница 40: ...r tender Full CW Max volume Check to see if a screw or some other material hasn t lodged itself in the underside of the chassis or tender Make sure smoke volume pot is turned full CW Make sure smoke v...

Страница 41: ...y power to the track my engine starts up lights and sound but it won t move My engine hesitates at slow speeds Lower the track voltage then raise it again The engine should start moving If you apply g...

Страница 42: ...to press the F21 button again to turn Doppler off Your engine sounds will now return to normal Check to see if a screw or some other material hasn t lodged itself in the underside of the engine Smoke...

Страница 43: ...CC controller to make your engine move PFA Solution I hit F4 to start the PFA but the engine just keeps ringing its bell that s all it ll do Why does my engine run away all by itself after the PFA is...

Страница 44: ...again to turn Doppler off Your engine sounds will now return to normal When I apply power to the track my engine doesn t do anything No lights no sound no nothing I get an error when I hit Start Up D...

Страница 45: ...lf after the PFA is over Press the DIR button Your engine will stop and begins the arrival sequence Pressing the DIR button will cycle you through the next 3 PFA sequences This is normal The engine wi...

Страница 46: ...Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Termina...

Страница 47: ...ctronic Electronic LGB Jumbo 50101 18VDC on Supply 0 18VDC at Controller 240 Watt Electronic MRC 6200 0 18 5v 60 Watt Electronic Not Recommended For 70 3001 1 J3a Not recommended for 70 3001 1 J3a REC...

Страница 48: ...sh stops all Proto Sound 2 0 and Proto Sound 3 0 engines but does not turn off the input power to the TIU One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives sou...

Страница 49: ...vice Centers If you need assistance at any time email MTH Service at service mth railking com or call 410 381 2580 Limited One Year Warranty All M T H products purchased from an M T H Authorized Retai...

Отзывы: