background image

Service & Warranty Information

How to Get Service Under the Terms of  the Limited One-Year Warranty

When you suspect an item is defective, please check the operator's manual for standard operation and trouble-
shooting techniques that may correct the problem.  Additional information may be found on the M.T.H. Website.  
Should you still require service, follow the instructions below to obtain warranty service.

First, e-mail, write, call or fax a M.T.H. Authorized Service Center (ASC) in your area to obtain Repair 
Authorization.  You can find the list of  ASCs on the M.T.H. Website, www.mthtrains.com.  Authorized Service 
Centers are required to make warranty repairs on items sold only from that store; all other repairs may-- or may not 
be done at the store's own discretion.  If  you did not purchase the item directly from the ASC, you will need to 
select a National Authorized Service Center (NASC).  These centers are compensated by M.T.H. to perform 
warranty service for any customer whose repair qualifies for warranty service.  A list of  NASC retailers can be 
located on the M.T.H. Website or by calling 410-381-2580.  Should the warranty no longer apply, you may choose 
either an ASC or NASC retailer to service your M.T.H. Product.  A reasonable service fee will be charged.

CAUTION:  Make sure the product is packed in its original factory packaging including its foam and plastic 
wrapping material to prevent damage to the merchandise.  There is no need to return the entire set if  only one of  
the components is in need of  repair unless otherwise instructed by the Service Center.  The shipment must be 
prepaid and we recommend that it be insured. A cover letter including your name, address, daytime phone number, 
e-mail address (if  available), Return Authorization number (if  required by the service center, a copy of  your sales 
receipt and a full description of  the problem must be included to facilitate the repairs.  Please include the 
description regardless of  whether you discussed the problem with a service technician when contacting the Service 
Center for your Return Authorization.

Please make sure you have followed the instructions carefully before returning any merchandise for service.  
Authorized M.T.H. Service Centers are independently owned and operated and are not agents or representatives of  
M.T.H. Electric Trains.  M.T.H. assumes no responsibility, financial or otherwise, for material left in their 
possession, or work done, by privately owned M.T.H. Authorized Service Centers.

If  you need assistance at any time email MTH Service at [email protected], or call 410 381-2580.

Limited One-Year Warranty

All M.T.H. products purchased from an M.T.H. Authorized Retailer are covered by this warranty provided the 
product was manufactured within five years of  the date of  purchase.  This warranty is for the original purchaser 
and is non-transferable.                       

See our website 

www.mthtrains.com

 to identify an M.T.H. Authorized Retailer near you. 

M.T.H. products may be registered online in advance of  warranty work at 

www.mthtrains.com/warranty

.  The 

original sales receipt and the conditions below must be met regardless of  whether the product is registered on the 
M.T.H. website in order to obtain warranty service.

M.T.H. products manufactured within five years from the date of  purchase are warrantied for one year against 
defects in material or workmanship, excluding wear items such as light bulbs, pick-up rollers, batteries, smoke unit 
wicks, and traction tires.  We will repair, replace, or credit (at our option) the defective part without charge for the 
parts or labor if  the following conditions are met: (1) the item is returned to an M.T.H. Authorized  Service 
Center* (ASC) or M.T.H. National Authorized Service Center (NASC) or M.T.H. Electric Trains Service 
Department, (2) was manufactured within the previous five years and (3) was purchased within one year of  the 
original date of  purchase from an M.T.H. Authorized Retailer. Products manufactured after the five year cutoff  
from the date of  purchase are not covered under any warranty by M.T.H. Electric Trains.  The manufacture date of  
an item can be verified on the item's detail page “shipping date field” on the M.T.H. website (www.mthtrains.com).  
This warranty does not cover damages caused by improper care, handling, or use.  Transportation costs incurred by 
the customer are not covered under this warranty.

Items sent for repair must be accompanied by a return authorization number, a description of  the problem, and a 

copy of  the original sales receipt from an M.T.H. Authorized Retailer

, which gives the date of  purchase.  If  you are 

sending this product to an Authorized Service Center, contact that Center for their return authorization.

This warranty gives you specific legal rights, and you may have other rights that vary from state to state.  Specific 
questions regarding the warranty may be forwarded to M.T.H. Directly.

* Authorized Service Centers (ASC) are only obligated to provide warranty service for any consumer who has 
purchased the specific M.T.H. item from them that requires service work. 

Service Department:
M.T.H. Electric Trains
7020 Columbia Gateway Drive
Columbia MD  21046-1532

Содержание Premier SD60E

Страница 1: ...alTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 46 47 for a complete list of compatible transformers power packs and wiring instructi...

Страница 2: ...brication 3 Priming the Smoke Unit 3 Configuring Locomotive for 2 Rail or 3 Rail Operation 4 PS 3 0 Enhancements 5 Conventional AC DC Start up Shut down 5 DCS DCC Switch 6 Programming Track for DCC op...

Страница 3: ...ons from the M T H Parts Department Lubrication You should lubricate the engine to prevent it from squeaking and to prevent excessive wear Use light household oil and follow the lubrication points mar...

Страница 4: ...rack To configure the locomotive for 2 Rail track operation please do the following 1 Remove the center rail pickup roller assemblies as seen in the figure below 2 Change the power input from 3 Rail t...

Страница 5: ...pacitors to hold the engine board alive for a short time when you shut off or interrupt track power Because of this when you first apply track power to your PS3 0 equipped O Gauge engine you will noti...

Страница 6: ...re available on our website MTH will make announcements as they are available Not all updates will apply to all engines NOTE Requires a TIU w version 4 20 or later firmware and requires Consumer Loade...

Страница 7: ...to 0 volts and back again will change the sequence to the forward state Then increasing the throttle will begin to move the engine forward and speed will increase as the throttle is advanced If there...

Страница 8: ...bell firmly press and release the Bell button To turn the bell off press and release the Bell button again The bell will continue to ring from the time you turn it on until you press and release the...

Страница 9: ...e control completely counterclockwise will turn of all of the engine sounds and announcements Feature to Be Activated Button Code Marker Lights 1 Bell 1 Horn Whistles PFA Passenger Freight Announcemen...

Страница 10: ...unit is temporarily disabled so that the train will not move as you use the Direction button to trigger the sounds Proto Sound 3 0 has disabled operator control over the Horn and Bell buttons until th...

Страница 11: ...conclusion of the PFA the engine will depart in the next direction of travel as opposed to the direction it was traveling before entering Neutral Proto Coupler Operation This locomotive is equipped wi...

Страница 12: ...d control on and off put the engine in neutral then quickly tap the transformer s Horn button one time then quickly tap the Bell button two times allowing approximately second to lapse between each qu...

Страница 13: ...button allowing approximately second to lapse between each quick button press Two horn blasts will indicate that the engine has made the change Reset Two Horn Blasts indicates change is made Repeat t...

Страница 14: ...age until the locomotive is traveling at the desired speed NOTE If you apply more than 9 0VDC to the engine at start up the engine will not move This is normal We refer to this as Anti Jackrabbit and...

Страница 15: ...have a slightly different F Function list This depends upon whether it s steam diesel or electric and whether it has smoke or not Please refer to the table of Default CV Values for your particular eng...

Страница 16: ...sets The bell will then begin ringing 2 Slowly reduce the throttle until the train stops at the desired location and speed reaches zero Press the F4 button twice toggle F4 on then off again and the be...

Страница 17: ...y controlled Proto Couplers They can be fired using your DCC handheld F7 Front Coupler Pressing F7 twice toggling on then off will fire your Front Coupler F8 Rear Coupler Pressing F8 twice toggling on...

Страница 18: ...Extended Start Up If your engine is shut down or you ve just applied DCC power pressing F17 twice toggling it on then off will start the Extended Start Up sounds This is very similar to F3 except you...

Страница 19: ...le it Then when you move the engine it will play the Coupler Slack sound The second way is to simply force the sound while the engine is moving To do this simply press F22 twice toggling it on then of...

Страница 20: ...Coupler F9 Forward Signal F10 Reverse Signal F11 Grade Crossing F12 Smoke On Off F13 Smoke Volume F14 Idle Sequence 3 F15 Idle Sequence 2 F16 Idle Sequence 1 F17 Extended Start Up F18 Extended Shut D...

Страница 21: ...ressing 4 Once you hit Enter the engine will give you a two whistle horn blast response 5 Call up the engine on its new address and away you go NOTE If you have elected to use PoM and did not start up...

Страница 22: ...please wait a minimum of 5 seconds after removing power to insure the settings are stored in the engines memory Reapplying power in less than 5 seconds may result in losing the setting changes If all...

Страница 23: ...e engine s address to 55 you are just telling the DCC system to start talking to engine address 55 You will want to make sure that no other M T H engines are on the rails or any other manufacturer s e...

Страница 24: ...Acceleration Rate CV24 Consist Deceleration Adjustment CV25 Speed Table Select CV29 Decoder Configuration CV49 Short Address controllers that prohibit PoM CV50 Extended Addr High Byte controllers that...

Страница 25: ...28 Reverse Trim User ID 1 User ID 2 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155...

Страница 26: ...ly in the engine SOUNDS Bell 1 Brake Sounds 2 Cab Chatter 3 Clickety Clack 4 Coupler Close 5 Coupler Slack 6 Drift Chuff 7 Engine Sounds 8 Forward Signal 9 Grade Crossing Signal 10 Horn 11 Idle Sequen...

Страница 27: ...8 on your DCC controller The engine will give you a two horn blast indication Note You ve also left an empty location where PFA used to be F4 5 Now you can fill that location with whichever CV you d l...

Страница 28: ...nored once the consist is removed CV19 set to 0 Setting the MSB Bit 7 of CV19 tells the engine that it is facing reverse in the consist Setting CV21 and CV22 determine which F Functions the consist re...

Страница 29: ...e F0 is deactivated at the Front engine s address Most systems have a light bulb icon to indicate whether F0 is active or not Ensure that it is OFF 5 Call up the Rear engine on your DCC handheld addre...

Страница 30: ...CV21 for a Consist CV21 allows you to set which F Functions you want the consist address to control For example you will likely want all of your MTH consist engines to respond to Start Up Shut Down F3...

Страница 31: ...garding CV22 Programming Track Your MTH Proto Sound 3 0 equipped locomotive does not program well on Programming tracks due to the inclusion of super capacitors utilized in the locomotive s electronic...

Страница 32: ...r example CV29 you would simply add the additional bits you enabled to the existing value to obtain the new CV value For example if you had a consist address CV19 set to 5 and you wanted to alter this...

Страница 33: ...only a drop or two on each pivot point The locomotive s internal gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes...

Страница 34: ...lied with a cotton swab To clean the track use RailKing Track Cleaning Fluid or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag fre...

Страница 35: ...ou may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you will need to remove and reinstall the tir...

Страница 36: ...ut After removing the engine from storage add another 25 drops of fluid letting the wick soak up the fluid for 15 minutes prior to operation Smoke Unit Cover Wick in Poor Condition Wick in Good Condit...

Страница 37: ...lting in extremely long life compared to the incandescent bulbs The LEDs are not user serviceable If you experience poor or no smoke output when the smoke unit is on and has fluid check the wick to se...

Страница 38: ...sending enough power to the track to power the engine Rotate throttle clockwise to increase track power Coupler Solution When I try to fire the coupler PFA starts The Proto Coupler won t let the engin...

Страница 39: ...gine doesn t go into reverse When the PFA enters its last sequence the bell automatically comes on When PFA is enabled pressing the whistle and bell has no effect I push the direction button but the n...

Страница 40: ...r tender Full CW Max volume Check to see if a screw or some other material hasn t lodged itself in the underside of the chassis or tender Make sure smoke volume pot is turned full CW Make sure smoke v...

Страница 41: ...y power to the track my engine starts up lights and sound but it won t move My engine hesitates at slow speeds Lower the track voltage then raise it again The engine should start moving If you apply g...

Страница 42: ...to press the F21 button again to turn Doppler off Your engine sounds will now return to normal Check to see if a screw or some other material hasn t lodged itself in the underside of the engine Smoke...

Страница 43: ...CC controller to make your engine move PFA Solution I hit F4 to start the PFA but the engine just keeps ringing its bell that s all it ll do Why does my engine run away all by itself after the PFA is...

Страница 44: ...again to turn Doppler off Your engine sounds will now return to normal When I apply power to the track my engine doesn t do anything No lights no sound no nothing I get an error when I hit Start Up D...

Страница 45: ...lf after the PFA is over Press the DIR button Your engine will stop and begins the arrival sequence Pressing the DIR button will cycle you through the next 3 PFA sequences This is normal The engine wi...

Страница 46: ...Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Termina...

Страница 47: ...ctronic Electronic LGB Jumbo 50101 18VDC on Supply 0 18VDC at Controller 240 Watt Electronic MRC 6200 0 18 5v 60 Watt Electronic Not Recommended For 70 3001 1 J3a Not recommended for 70 3001 1 J3a REC...

Страница 48: ...sh stops all Proto Sound 2 0 and Proto Sound 3 0 engines but does not turn off the input power to the TIU One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives sou...

Страница 49: ...vice Centers If you need assistance at any time email MTH Service at service mth railking com or call 410 381 2580 Limited One Year Warranty All M T H products purchased from an M T H Authorized Retai...

Отзывы: