background image

Section 

T51 • E51

  Page 511

Dated 

February 2014

Figure 4-5  

C3 - D3 VERTICAL FLANGE

MOUNT PUMP

15

14

1

7

125

12

23

11

23A

60

19

2

18

20

8

T51 C3

3.  Remove the cover.  In some 

cases light tapping with a plastic 

or wooden mallet on the outside 

diameter of the cover may be 

required to loosen it from the 

motor bracket.  Care should be 

taken if a screwdriver is needed to 

pry between the cover and motor 

bracket.  Damage to the “O” ring 

(#7) and/or impeller (#11) can 

result.

4.  Remove the impeller(#11), refer to 

Figure 4-11.  This is easily done 

by setting the motor on end.  The 

impeller is a slip fit and under nor

-

mal conditions, can be removed 

by hand or by gently tapping on 

the end of the shaft with a mal-

let.  Striking the shaft too hard 

could damage the seat, rotat-

ing element, or the motor.  After 

removing the impeller, the impeller 

key (#23) needs to be removed 

from the shaft keyway.

5.  Remove the snap ring (#4) from 

the shaft; note the spring that is 

held in place by the snap ring.  

Remove the spring from the shaft.

6.  To remove the rotating element 

(#12), gently slide the motor 

bracket (#1) forward on the shaft 

to move the rotating element 

high enough to be removed by 

hand.  Using tools on the rotating 

element may damage the rotating 

element or the seat.  Take precau-

tions to keep the rotating element 

clean if it is to be reused.

7.  Next remove the motor bracket.

8.  To remove the seat (#125).  Refer 

to Figure 4-12.  Place the motor 

bracket face down on a clean flat 

surface.  Look into the opening in 

the center of the motor bracket, 

and you will see a portion of the 

seat.  Insert the 1” dowel and, 

very gently, tap the seat  until it 

drops out.  Care must be taken 

with the seat.  It is often a brittle 

material and is prone to breakage. 

 

It is

 

recommended that a new 

replacement seat be installed 

during reassembly.

4E Inspection of Components

Thoroughly clean all parts.  All 

components should be examined for 

wear and corrosion.  Replace any 

parts that show visible wear.  If the 

pump was not producing sufficient 

pressure or capacity, the clearances 

between the casing and impeller 

probably exceed the maximum al-

lowable clearance.  At minimum, the 

impeller should be replaced in this 

case.  If the total side running clear-

ance for an impeller exceeds .007”, it 

is unlikely that pump performance will 

reach that of a new pump except at 

lower discharge pressures.

The “O” rings and other elastomeric 

components should be replaced if 

they have been deformed or cut.

If seal components must be reused, 

carefully inspect for microscopic 

E51 D3

17

125

12

11

23

T51

E51

Figure 4-11

Figure 4-12

NAME/DESCRIPTION

PART NO. QTY.

Motor Bracket

1

1

Cover/Vertical

2

1

“O” Ring/Casing

7

1

“O” Ring/Guide Rod

8

4

Impeller

11

1

Snap Ring

4

1

Seal Rotating Element

12

1

Seal Stationary Seat

125

1

Lock Collar/Sleeve

14

1

Setscrew/Lock Collar

15

2

Shaft Sleeve

17

1

Guide Rod

18

2

ThruBolt

19

2

Nut

20

2

Pipe Plug/Drain

22

1

Key/Impeller Drive

23

1

Key/Sleeve Drive

23A

1

Gasket

60

1

4

Содержание E51 SERIES

Страница 1: ...ction T51 E51 Page 501 Dated February 2014 97 4623 01 588 T51 E51 SERIES Pump Manual Distributed in the UK by Pump Engineering Limited Unit B1 Riverside Industrial Estate Littlehampton West Sussex BN17 5DF United Kingdom Tel 01903 730900 Fax 01903 730234 email sales pumpeng co uk Web www pumpeng co uk ...

Страница 2: ...ose coupled units access to the shaft is between the pump and motor A vise grip or other plier type gripping device may be used directly on the shaft Apply ing torque to the motor fan blades is not recommended If the impeller does not break loose immediately fill the pump with a process compatible fluid and try again in a few hours If this fails loosen only the pump cov er thru bolts clamping the ...

Страница 3: ... as possible when the pump is started This will reduce the start up load on the pump and motor Never start the pump with the discharge valve closed The inlet valving should be open when starting any pumping system Without some fluid in the pump it can gall and lock up impellers Violent pump failure will result from contin ued operation with the inlet valve closed 1D4 Priming Regardless of whether ...

Страница 4: ... properly aligned The foundation must be a perma nent rigid installation of concrete or other material of sufficient mass to absorb all normal vibrations Locate the foundation bolts using a layout or template in relation to the suction and discharge piping If concrete is being used foundation bolts of the specified size can be enclosed in a pipe sleeve two to three diameters larger than the bolts ...

Страница 5: ... the lines are ended at the pump particularly if the last piece is cut a little too short or long the pump will be forced to meet the pipe and strain or distortion will result 2E2 Piping Support Never allow the pump to support piping Other means such as pipe hangers and pipe supports should be used to carry piping to avoid misalignment and distortion Consid eration should be given to thermally ind...

Страница 6: ...he pump If a new pump does not oper ate properly the first thing to check for is damage from foreign material 3D Electrical It is important to be aware of and fol low the appropriate local and national electrical codes Do not make wiring alterations that can affect motor rotation without reconfirming correct rotation Select starter heaters and wiring for the maximum current the motor can use at fu...

Страница 7: ... valve necessary to maintain a vacuum in the suc tion line as surging occurs in the pump 2 An air eliminator used on the discharge side of the pump to separate air from liquid so the liquid can be used again as air is carried through the pump 3 A recirculating line carries liquid from the air eliminator to the suc tion 4 A fluid chamber used on the inlet side to provide a supply of fluid to speed ...

Страница 8: ...to Figures 4 4 and 4 5 for refer ence to the numbered parts in the procedures below 1 Remove all liquid from the pump Air blown through the pump will remove the water quickly 2 Remove the two 2 nuts 20 and the two 2 3 8 X 4 bolts 19 from the cover 2 3 Remove the cover In some cases light tapping with a plastic or wooden mallet on the outside diameter of the cover may be required to loosen it from ...

Страница 9: ...s 4 11 and 4 12 for reference to the numbered parts in the disassembly below 1 Remove all liquid from the pump 2 Remove the two 2 3 8 nuts 20 and the two 2 3 8 X 4 bolts 19 from the cover 2 3 Remove the cover In some cases light tapping with a plastic or wooden mallet on the outside diameter of the cover may be required to loosen it from the motor bracket Care should be taken if a screwdriver is n...

Страница 10: ... is recommended that a new rotating element be used for reassembly DO NOT attempt to remove the seal using a screwdriver or other sharp object Damage to the shaft or element can occur 7 Before the motor bracket 1 can be removed the four 4 O rings 8 located on the upper left and right studs must be removed a Gently tap on the back of the motor bracket alternating between the left and right side unt...

Страница 11: ...t 125 Refer to Figure 4 12 Place the motor bracket face down on a clean flat surface Look into the opening in the center of the motor bracket and you will see a portion of the seat Insert the 1 dowel and very gently tap the seat until it drops out Care must be taken with the seat It is often a brittle material and is prone to breakage It is recommended that a new replacement seat be installed duri...

Страница 12: ...ts should be visually inspected and cleaned or replaced as outlined in 4D above 1 The seal seat 125 must be in stalled in the motor bracket before the bracket is installed on the mo tor To install the seat a Place the motor bracket face up on a flat surface b Carefully press the seat smooth side up into the seat cavity of the motor bracket To make the installation of the seat easier apply a thin c...

Страница 13: ...impel ler wearing surface Force should not be required to install the impeller in the correct posi tion c The impeller hub should be facing out away from the motor bracket Refer to Figure 4 4 and 4 5 d If the impeller does not fit repeat steps a and b to deter mine the problem 5 Place O ring 7 into the O ring groove in the motor bracket It is helpful to stand the motor and pump assembly on end for...

Страница 14: ...placed as outlined in 4E above 1 The stationary seat 125 must be installed in the motor bracket before the bracket is installed on the motor To install the seat a Place the motor bracket face up on a flat surface b To make the installation of the seat easier apply a thin coating of compatible lubricant to the elastomer portion of the seat prior to installation c Carefully press the seat smooth sid...

Страница 15: ...mpeller wearing surface Force should not be required or used to install the impeller in the correct position The impeller hub should be facing out away from the motor bracket Refer to Figures 4 4 and 4 5 7 Next rotate the impeller by hand the impeller should move freely 8 Place the large O ring 7 into the outside O ring groove in the motor bracket 9 Place the cover over the motor bracket and insta...

Страница 16: ...ion 4 T51 PUMP ENDS All work on the unit should be per formed on an elevated workbench whenever possible The disassembly and reassembly procedures are broken into two sec tions covering the following units 4B Disassembly of the P3 and P15 Bearing Pedestals 4D Reassembly of the P3 and P15 Bearing Pedestals Exploded views of each unit Figures 4 19 and 4 20 are provided for refer encing the numbers i...

Страница 17: ...t using the following procedure This procedure is not recommended and should only be used in an emer gency situation 1 Stand a piece of 3 4 pipe for P3 or a 1 1 4 piece of pipe for P15 with the threads cut off on a work bench or similar flat surface with the bearing placed on the correct shaft end 2 Insert the shaft into the pipe so the bearing is between the pipe and the shoulder of the shaft Ref...

Страница 18: ...system with fluid and hydrostatically test Tighten connections or replace leaky components 2 Air entering pump through inlet seal or O rings Hydrostatically test the pump and look for leaks Replace faulty seals or O rings 3 Insufficient NPSH or too much suc tion lift Relocate pump supply tank or both to improve inlet con ditions Increase suction pressure Reduce fluid temperature Select a pump with...

Страница 19: ...t If a seal has recently been replaced look for a missing O ring cup around the seat or a seat that was installed cocked or backwards The smooth surface should face the rotating element The rotating element may be in backward or improperly posi tioned Refer to the appropriate seal diagrams and instructions to confirm the correct seal orientation Rotating elements sometimes stick in the wrong posit...

Страница 20: ...thout an RGA will be refused at the dock Products authorized for return must be properly packaged to prevent further damage clearly marked with the Return Goods Authorization RGA number provided by MTH and shipped freight prepaid and allowed F O B the MTH factory at Plano Illinois USA MTH may in its sole discretion deny any warranty claim if shipping damage any attempted disassembly or any other a...