Po ly Gar d ® 2 M SC 2  –  Dat a Sh eet  an d   Us er  M an u al  

MSR-Electronic GmbH

 ::: Würdinger Str. 27 + 27A ::: 94060 Pocking 

::: Germany 

Specifications subject to change without notice 

PolyGard® is a registered trademark of MSR-Electronic GmbH 

 

CONFIGURATION AND PARAMETER CARDS 

Commission: 

           

Order number: 

           

Customer: 

           

Service technician: 

           

Commissioning - company: 

             

Date 

           

 

Configuration Card System Parameters 

Serial 

No. 

Date of 

Production 

Mainten. 

interval 

Mainten. 

Password 

AV Overlay 

AV Time 

Power On 

Time 

Error 
Time 

CFM 

dupl. 

Note  

Note down 

1900 

**** 

V-time 

ppm 

 

 

 

 

 

 

 

90 

30 

30 

 

 

 

 

 

 

 

 

 

 

 

 

Analog Output 1 

Outp. 

source 

Oper. 

Signal 

 

Mode 

100% 

CV 

MAX 

 

 

 

 

Relay Multiplication 

In 

Out 

In 

Out 

In 

Out 

In 

Out 

In 

Out 

 

 

 

 

 

 

 

 

 

 

 

Configuration Card Alarm Relays / Signal Outputs 

R 01 

active 

energ. 

 

 

 

 

 

 

 

 

 

 

R 02 

active 

energ. 

 

 

 

 

 

 

 

 

 

 

R 03 

active 

de-en 

 

 

 

 

 

 

 

 

 

 

Horn 

active 

de-en 

 

 

 

 

 

 

 

 

 

 

LED red 

active 

de-en 

flash 

 

 

 

 

 

 

 

 

 

 

Relay 

No. 

active 

inactive 

Mode 

Stat. 

Flash 

Reset 

Horn 

 

Extern. 

On 

Extern. 

Off 

Delay 

at ON 

Delay 

at OFF 

Fault 

ORed 

Maint. 

ORed 

 

 

 

 

Time 

Recur. 

DI 

DI 

DI 

sec 

sec 

 

 

Default 

inactive 

de-en 

Stat. 

no 

OFF 

OFF 

Содержание PolyGard 2 MSC2

Страница 1: ...bH W rdinger Str 27 27A 94060 Pocking Germany Specifications subject to change without notice PolyGard is a registered trademark of MSR Electronic GmbH PolyGard 2 MSC2 Multi Sensor Controller Datashee...

Страница 2: ...5 interface with serial protocol For convenient operation the MSC2 is already completely configured and parameterized ex works The intended sites within the ambient conditions as specified in the Tech...

Страница 3: ...Buzzer status LED red yellow green ALARM RELAYS 3 3x Alarm relays POWER SUPPLY 5 90 240 V AC 24 V DC 5 VA 7 90 240 V AC 24 V DC 15 VA HOUSING C Housing type C 130 x 130 x 75 mm ELECTRICAL CONNECTION...

Страница 4: ...W Note Relay 1 2 Status OFF means Alarm off Relay coil energized Status ON means Alarm on Relay coil de energized Note Relay 3 Status OFF means No fault and MSC2 in normal operation Relay coil energiz...

Страница 5: ...n flashing represents a connection option for warning devices to improve visibility If flashing is set this must not be used as a safe output circuit any more A combination of relay mode energized wit...

Страница 6: ...from above the sensor head SC downwards Observe possible constructor s instructions Mounting Controller Wiring The technical requirements and regulations for wiring electrical security fire protection...

Страница 7: ...in the field because it is here where most of the causes for problems in the field bus communication appear Optical Check Right cable type used Correct mounting height according to definition in Moun...

Страница 8: ...100 Vol 2066 R11 R11 ppm 2059 R12 R12 20 2000 ppm 2070 R22 R22 20 300 ppm 2061 R23 R23 20 2000 ppm 2060 R32 R32 ppm 2064 R123 R123 20 300 ppm 2077 R134a R134a 20 300 ppm 2063 R1234yf R1234yf ppm 2065...

Страница 9: ...erial No Date of Production Mainten interval Mainten Password AV Overlay AV Time Power On Time Error Time CFM dupl Note Note down 1900 V time ppm 0 0 0 90 30 30 Analog Output 1 Outp source Oper Signal...

Страница 10: ...1 A2 A3 A4 A1 A2 A3 A4 01 active n CO2 Vol 5 0 5 1 1 1 0 2 0 0 CV 0 0 0 0 1 R1 R2 R3 R4 02 inactive n 03 inactive n Change of values after replugging the jumper closed 01 active n CO2 Vol 5 1 1 8 1 1...

Страница 11: ...utton on the horn the horn acknowledgment must be checked After removal of the reference gas all outputs must automatically return to its initial position Other than the simple functional testing it i...

Страница 12: ...y third parties every customer receives his own internal project key All projects of the customer are delivered with this key The key is also stored in each MSC 06 STL Tool that the respective custome...

Страница 13: ...WH BL24 Tast SPECIFICATIONS SENSOR CARTRIDGE Sensor element Gas type Carbon dioxide CO2 Sensor element Infrared NDIR Measuring range 5 vol Measuring interval 2 sec Accuracy 10 of range Response time t...

Страница 14: ...rol installations and the latest edition of the National Electrical Code ANSI NFPA70 The equipotential bonding required also e g secondary potential to earth or grounding measures must be carried out...

Страница 15: ...MSR Electronic GmbH W rdinger Str 27 27A 94060 Pocking Germany Specifications subject to change without notice PolyGard is a registered trademark of MSR Electronic GmbH...

Отзывы: