Page 14

 | Dec. 2015 

 

Po ly Gar d ® 2 M SC 2  –  Dat a Sh eet  an d   Us er  M an u al  

Specifications subject to change without notice 

PolyGard® is a registered trademark of MSR-Electronic GmbH 

 

NOTES AND GENERAL INFORMATION 

It is important to read this user manual carefully in order to understand the information and instructions. The PolyGard®2 
MSC system may only be used for applications in accordance to the intended use. The appropriate operating and 
maintenance instructions and recommendations must be followed. 

Due to permanent product developments, MSR-E reserves the right to change specifications without notice. The 
information contained herein is based on data considered to be accurate. However, no guarantee or warranty is 
expressed or implied concerning the accuracy of these data. 

Intended Product Application 

The PolyGard®2 MSC system is designed and manufactured for controlling, for saving energy and keeping OSHA air 
quality in commercial buildings and manufacturing plants. 

Installer’s Responsibilities 

It is the installer’s responsibility to ensure that all PolyGard®2 MSC systems are installed in compliance with all national 
and local regulations and OSHA requirements. All installation shall be executed only by technicians familiar with proper 
installation techniques and with codes, standards and proper safety procedures for control installations and the latest 
edition of the National Electrical Code (ANSI/NFPA70).  
The equipotential bonding required (also e.g. secondary potential to earth) or grounding measures must be carried out in 
accordance with the respective project requirements. It is important to ensure that no ground loops are formed to avoid 
unwanted interference in the electronic measuring equipment. 
It is also essential to follow strictly all instructions as provided in the user manual. 

Maintenance 

We recommend checking the PolyGard®2 MSC system regularly. Due to regular maintenance differences in efficiency can 
easily be corrected. Re-calibration and replacement of parts can be realised on site by a qualified technician with the 
appropriate tools. A separate documentation is available for this. Alternatively the removable Gas Controller can be 
returned to MSR-Electronic GmbH for services. 

Limited Warranty 

MSR-Electronic GmbH warrants the PolyGard®2 MGC system against defects in material or workmanship for a period of 
one (1) year beginning from the date of shipment. Should any evidence of defects in material or workmanship occur 
during the warranty period, MSR will repair or replace the product at their own discretion, without charge. This warranty 
does not apply to units that have been altered, had attempted repair, or been subjected to abuse, accidental or 
otherwise. The above warranty is in lieu of all other explicit warranties, obligations or liabilities. 

This warranty extends only to the PolyGard®2 MSC system. MSR-Electronic GmbH shall not be liable for any incidental or 
consequential damages arising out of or related to the use of the PolyGard®2 MSC systems. 

Содержание PolyGard 2 MSC2

Страница 1: ...bH W rdinger Str 27 27A 94060 Pocking Germany Specifications subject to change without notice PolyGard is a registered trademark of MSR Electronic GmbH PolyGard 2 MSC2 Multi Sensor Controller Datashee...

Страница 2: ...5 interface with serial protocol For convenient operation the MSC2 is already completely configured and parameterized ex works The intended sites within the ambient conditions as specified in the Tech...

Страница 3: ...Buzzer status LED red yellow green ALARM RELAYS 3 3x Alarm relays POWER SUPPLY 5 90 240 V AC 24 V DC 5 VA 7 90 240 V AC 24 V DC 15 VA HOUSING C Housing type C 130 x 130 x 75 mm ELECTRICAL CONNECTION...

Страница 4: ...W Note Relay 1 2 Status OFF means Alarm off Relay coil energized Status ON means Alarm on Relay coil de energized Note Relay 3 Status OFF means No fault and MSC2 in normal operation Relay coil energiz...

Страница 5: ...n flashing represents a connection option for warning devices to improve visibility If flashing is set this must not be used as a safe output circuit any more A combination of relay mode energized wit...

Страница 6: ...from above the sensor head SC downwards Observe possible constructor s instructions Mounting Controller Wiring The technical requirements and regulations for wiring electrical security fire protection...

Страница 7: ...in the field because it is here where most of the causes for problems in the field bus communication appear Optical Check Right cable type used Correct mounting height according to definition in Moun...

Страница 8: ...100 Vol 2066 R11 R11 ppm 2059 R12 R12 20 2000 ppm 2070 R22 R22 20 300 ppm 2061 R23 R23 20 2000 ppm 2060 R32 R32 ppm 2064 R123 R123 20 300 ppm 2077 R134a R134a 20 300 ppm 2063 R1234yf R1234yf ppm 2065...

Страница 9: ...erial No Date of Production Mainten interval Mainten Password AV Overlay AV Time Power On Time Error Time CFM dupl Note Note down 1900 V time ppm 0 0 0 90 30 30 Analog Output 1 Outp source Oper Signal...

Страница 10: ...1 A2 A3 A4 A1 A2 A3 A4 01 active n CO2 Vol 5 0 5 1 1 1 0 2 0 0 CV 0 0 0 0 1 R1 R2 R3 R4 02 inactive n 03 inactive n Change of values after replugging the jumper closed 01 active n CO2 Vol 5 1 1 8 1 1...

Страница 11: ...utton on the horn the horn acknowledgment must be checked After removal of the reference gas all outputs must automatically return to its initial position Other than the simple functional testing it i...

Страница 12: ...y third parties every customer receives his own internal project key All projects of the customer are delivered with this key The key is also stored in each MSC 06 STL Tool that the respective custome...

Страница 13: ...WH BL24 Tast SPECIFICATIONS SENSOR CARTRIDGE Sensor element Gas type Carbon dioxide CO2 Sensor element Infrared NDIR Measuring range 5 vol Measuring interval 2 sec Accuracy 10 of range Response time t...

Страница 14: ...rol installations and the latest edition of the National Electrical Code ANSI NFPA70 The equipotential bonding required also e g secondary potential to earth or grounding measures must be carried out...

Страница 15: ...MSR Electronic GmbH W rdinger Str 27 27A 94060 Pocking Germany Specifications subject to change without notice PolyGard is a registered trademark of MSR Electronic GmbH...

Отзывы: