Cleaning the Filter CARTRIDGE
Please make sure to unplug the power pack from the electrical receptacle before the follwoing
actions.
1. Unscrew the filter cartridge by turning it coun-
terclockwise
2. Remove the filter cartridge cover.
3. The Filter Cartridge can be rinsed off with a gar-
den hose and reused. However, if the Filter Cartridge
remains soiled and discolored the Filter Cartridge
should be replaced .
4. Put on the filter cartridge cover and place the
filter cartridge to water inlet by turning it clock-
wise
Heat Button: Use this button to activate the heating system.
The heater does not stop heating the Spa until the current water temperature reaches 1°C higher
than the set temperature.
After the current water temperature drops 2°C below the set point temperature the heating sys-
tem will restart.
When the light of the Heat Button displays green, the heating system is activate
Heating system is capable of increasing approximately 1.5 to 2°F per hour.
NOTE: If the heating system is activated the filtration system will automatically start – This is
normal.
NOTE: After turning off the heating system the filtration system will still work. This is normal.
Caution:
Attention: When “HEATER” and “FILTER” both are on, only pressing “HEATER” button can switch
off filtering function but not “FILTER” button.
Bubble Button: Press this button to activate the massage system which has a 30-minute auto
shut off for 10 minutes feature.