#2: RUNNING THE FLASH CURE IN INTERNAL MODE

 

 

With the MHM main computer set for Flash Internal Mode, program the desired flash time. 

 

When the first platen programmed to flash moves under the flash cure unit it will flash for the  

 

Time programmed and another cycle will begin. 

 

In this mode, the temperature sensor module will still shut the flash unit off at the programmed  

temperature “set

-

point”. It may be necessary to raise the temperature controller’s “set

-

point” to 

a slightly higher setting.  
This may or may not be required and your experience will guide you through this decision. 
 
 

#3:  RUNNING THE FLASH WITH AN EXTERNAL SENSOR 

The dwell timer should be set to “D” mode and the desired flash time must be set on the dwell 

timer. 
The temperature controller will still turn the flash unit off when the substrate reaches the 

temperature set on the temp controller.  In this mode, you may find it helpful to raise the “set

-

point” of the controller.

 

 
     

The Following information does not apply to the newer Controllers, these cannot be 

taken out of “RUN “ mode.

 

If you have a older version of the controller and it is taken out of “RUN” 

mode follow instructions below.

 

 

 #4 - CAUTION:

  

Be aware that by changing the “set

-

point” there is a

 chance that the temp control 

module may have been taken out of run mode if you accidentally hit one of the arrow keys while 
exiting the menu. 

 
           

If you do not have the word “RUN” lighted in red on the left side of the temperature control 

module, then you may have accidentally changed a setting.  

           

(You must have the control module set to show the word “RUN” in red to operate in external 

   

mode and use the temperature control feature. If not in “RUN” mode the machine will only run 
one cycle and an error will appear on the machine’s

 computer.) 

 
           With the temperature control module displaying the digits of the current temperature  STEADY ON   

and NOT FLASHING, follow these steps to correct the setting: 

 
           -

Press the “P” button 3 times. After the 3

rd

 time, the contro

ller will be flashing “RUN –

 NO 

 RUN 

   

NO”

 

           -

Change the flash setting sequence to “RUN –

 YES 

 RUN 

 

YES” by pressing the down arrow 1 time.

 

           

Now the controller display will begin to flash  “RUN –

 YES 

 RUN 

 

YES”.

 

           -Press 

the “P” button 1 time and the controller will go back to showing the digits of current 

   

temperature       (a low reading from the floor or a cold pallet). 

           

The word “RUN” will be lighted in red on the left side of the temperature controller ind

icating      

that the module is set to run and the flash unit is ready for production. 

 
 
 
 
 
 
 
 

                                                                      8 

                                  

Содержание TC 1000

Страница 1: ...sh TC TC 1000 Features Machine Interface Temperature Control Three Individual Zones VersiFlashTC Features Machine Interface Temperature Control Intensity Control Three Individual Zones Stand By Mode w...

Страница 2: ...Index Safety Pg 2 Bulb Installation Pg 3 4 Initial Setup Pg 5 Operational Controls Pg 6 Operating Instructions Pg 7 8 Components Reference Pg 9 10 Parts List Pg 11 1...

Страница 3: ...Flash Above your Pallet is also very important Make sure that all control features are checked and adjusted prior to every production run Check Pallet Clearance Temperature Control and Power Before E...

Страница 4: ...ft off cover UNPACK AND INSTALL BULBS ONE AT A TIME HANDLING THEM BY THE ENDS ONLY Feed bulb wires one side at a time through outer holes next to bulb clips in reflector pan and insert ceramic ends in...

Страница 5: ...inal Hook up wires from the right side to position 2 right terminal of the same block See fig 4 The next group of bulbs center of unit will use 2 ceramic blocks these are Zone 2 The bulb wires from th...

Страница 6: ...unit is completely unplugged from its electrical service Make sure to allow the bulbs and housing a minimum of 15 minutes to completely cool off before attempting to handle the unit and replace the b...

Страница 7: ...is comfortable with the best settings for their shop STANDBY TEMP The Standby mode is pre set to come on for 20 seconds after every flashcycle When in stand by mode the lamps can emit up to 30 of maxi...

Страница 8: ...our MHM dealer and they will assist you with this setting change PRE HEATING THE PLATENS Because of the nature of the honeycomb pallets you will find that pre heating the platens should be done with a...

Страница 9: ...tructions below 4 CAUTION Be aware that by changing the set point there is a chance that the temp control module may have been taken out of run mode if you accidentally hit one of the arrow keys while...

Страница 10: ...BULB CLIP COMPLETE X VF9 A 115 VOLT OMRON SENSOR X VF9 B 24 VOLT SENSOR PEPPREL FUCHS X X VF10 A STAND BY TEMP POT X X VF10 B HIGH TEMP POT X X X VF11 A ZONE CONTROL ROCKER SWITCH X X X VF11 B ZONE L...

Отзывы: