WIRING BULBS CONTINUED:

With the Flash Unit in front of you ( back of 
control box facing you ) 

See fig. 3 

Start 

attaching bulb wires to ceramic blocks in 
groups of 3 (9 bulb units) or 4 (12 bulb units) 
Insulation on the bulb wires is striped back 
about 

½

 inch and they are ready to install.

  The first group of bulbs nearest to the 
control box are 

Zone 1. 

Locate this group of 

wires from the left side and hook them to the 
ceramic block for 

Zone 1 

by inserting them 

under the tab and tightening screw at 
position #1 (left terminal). Hook up wires 
from the right side to position # 2 (right 
terminal) of the same block 

See fig. 4

The next group of bulbs (center of unit) will 
use 2 ceramic blocks, these are 

Zone 2

. The 

bulb wires from the left side will hook up to 
the ceramic block on the left position # 2 and 
the wires from the right side will hook up to 
the ceramic block on the right position # 1

The remaining group of bulbs (furthest from 
control box) are 

Zone 3. 

These will hook up 

to the remaining ceramic block. Wires from 
the left side will go to position # 1 and wires 
from the right side will go to position # 2

FIG. 3

Zone 1 Block

Zone 3 
Block

Zone 2 
Blocks

Sensor 
Cutout

FIG.  4

IMPORTANT: Make sure all connections are tight before 
installing cover!                

Содержание TC 1000

Страница 1: ...sh TC TC 1000 Features Machine Interface Temperature Control Three Individual Zones VersiFlashTC Features Machine Interface Temperature Control Intensity Control Three Individual Zones Stand By Mode w...

Страница 2: ...Index Safety Pg 2 Bulb Installation Pg 3 4 Initial Setup Pg 5 Operational Controls Pg 6 Operating Instructions Pg 7 8 Components Reference Pg 9 10 Parts List Pg 11 1...

Страница 3: ...Flash Above your Pallet is also very important Make sure that all control features are checked and adjusted prior to every production run Check Pallet Clearance Temperature Control and Power Before E...

Страница 4: ...ft off cover UNPACK AND INSTALL BULBS ONE AT A TIME HANDLING THEM BY THE ENDS ONLY Feed bulb wires one side at a time through outer holes next to bulb clips in reflector pan and insert ceramic ends in...

Страница 5: ...inal Hook up wires from the right side to position 2 right terminal of the same block See fig 4 The next group of bulbs center of unit will use 2 ceramic blocks these are Zone 2 The bulb wires from th...

Страница 6: ...unit is completely unplugged from its electrical service Make sure to allow the bulbs and housing a minimum of 15 minutes to completely cool off before attempting to handle the unit and replace the b...

Страница 7: ...is comfortable with the best settings for their shop STANDBY TEMP The Standby mode is pre set to come on for 20 seconds after every flashcycle When in stand by mode the lamps can emit up to 30 of maxi...

Страница 8: ...our MHM dealer and they will assist you with this setting change PRE HEATING THE PLATENS Because of the nature of the honeycomb pallets you will find that pre heating the platens should be done with a...

Страница 9: ...tructions below 4 CAUTION Be aware that by changing the set point there is a chance that the temp control module may have been taken out of run mode if you accidentally hit one of the arrow keys while...

Страница 10: ...BULB CLIP COMPLETE X VF9 A 115 VOLT OMRON SENSOR X VF9 B 24 VOLT SENSOR PEPPREL FUCHS X X VF10 A STAND BY TEMP POT X X VF10 B HIGH TEMP POT X X X VF11 A ZONE CONTROL ROCKER SWITCH X X X VF11 B ZONE L...

Отзывы: