DWELL TIMER
(for external sensor only)
When using flash with an external sensor, the Dwell Timer
should be set to “D”. The time setting will determine the
length of the flash–cure cycle. When using the Test button,
the Dwell Timer will determine the test cycle time.
Operational Controls
Read Carefully
HIGH TEMP
Controls the level of power being radiated during
a flash cycle. It should be adjusted and confirmed
before each production run until the operator is
comfortable with the best settings for their shop.
STANDBY TEMP
The Standby mode
is pre-set to come on
for 20 seconds after
every flashcycle.
When in stand by
mode, the lamps
can emit up to
30% of maximum
temperature
depending on setting.
TEMPERATURE CONTROLLER
Used for setting the Set Point or cure
temperature in external mode.
ZONE CONTROLS 1, 2, and 3
Each unit has three user controlled zones to allow the operator
to cure only the neccessary areas. This wil minimize your electric
bill and has additional benefits. Any combination of zones are
available to use at one time. Momentarily push the Test
contol button
to observe which zones are selected.
6