TC 1000 and VersiFlash TC

TC 1000 Features:

Machine Interface • Temperature Control

Three Individual Zones

VersiFlash

 TC Features: 

Machine Interface • Temperature Control • Intensity Control 

Three Individual Zones • Stand By Mode with Intensity Control 

Dwell Timer (for use with External Sensor)

Содержание TC 1000

Страница 1: ...sh TC TC 1000 Features Machine Interface Temperature Control Three Individual Zones VersiFlashTC Features Machine Interface Temperature Control Intensity Control Three Individual Zones Stand By Mode w...

Страница 2: ...Index Safety Pg 2 Bulb Installation Pg 3 4 Initial Setup Pg 5 Operational Controls Pg 6 Operating Instructions Pg 7 8 Components Reference Pg 9 10 Parts List Pg 11 1...

Страница 3: ...Flash Above your Pallet is also very important Make sure that all control features are checked and adjusted prior to every production run Check Pallet Clearance Temperature Control and Power Before E...

Страница 4: ...ft off cover UNPACK AND INSTALL BULBS ONE AT A TIME HANDLING THEM BY THE ENDS ONLY Feed bulb wires one side at a time through outer holes next to bulb clips in reflector pan and insert ceramic ends in...

Страница 5: ...inal Hook up wires from the right side to position 2 right terminal of the same block See fig 4 The next group of bulbs center of unit will use 2 ceramic blocks these are Zone 2 The bulb wires from th...

Страница 6: ...unit is completely unplugged from its electrical service Make sure to allow the bulbs and housing a minimum of 15 minutes to completely cool off before attempting to handle the unit and replace the b...

Страница 7: ...is comfortable with the best settings for their shop STANDBY TEMP The Standby mode is pre set to come on for 20 seconds after every flashcycle When in stand by mode the lamps can emit up to 30 of maxi...

Страница 8: ...our MHM dealer and they will assist you with this setting change PRE HEATING THE PLATENS Because of the nature of the honeycomb pallets you will find that pre heating the platens should be done with a...

Страница 9: ...tructions below 4 CAUTION Be aware that by changing the set point there is a chance that the temp control module may have been taken out of run mode if you accidentally hit one of the arrow keys while...

Страница 10: ...BULB CLIP COMPLETE X VF9 A 115 VOLT OMRON SENSOR X VF9 B 24 VOLT SENSOR PEPPREL FUCHS X X VF10 A STAND BY TEMP POT X X VF10 B HIGH TEMP POT X X X VF11 A ZONE CONTROL ROCKER SWITCH X X X VF11 B ZONE L...