2Q2II
2Q
3ULQW
RF Setup Procedure
VFLG
U)
example SCID Value
blinking
blinking
Error Correction: If you input a wrong value, press
ZERO
to step
back one digit and reenter.
&KQ/
blinking
1) With the power on, open the
COMM setup menu by
pressing the
F1
and
F2
keys
simultaneously.
The COMM setup menu
choice is
.
2) Press
F2
to scroll to the RF
setup menus.
3) Press
F1
to enter the RF
setup menu.
4) The display reads
OnOff
by pressing
F1
. If it is off,
use the
F2
key to change it
to on. Then push
F1
.
Off is only used when the 8000 is
hardwired to a Dyna-Link.
5) Press
F1
. Next the
Scid
(ScaleCore ID) screen is
shown
6) Press
F1
. The current SCID
number is shown.
If the offered SCID value is correct,
push
F1
and jump to step 10.
In this example we’ll enter 3 as an SCID
number. Any value from 1-254 is
acceptable. However, MSI
recommends a value from 20 – 30.
7) To input the SCID value,
press
F2
to start the number
entry process.
8) Use
F2
to change the
number, and
F1
to enter
the number. Add the next
digit by pushing
F2
and
scrolling as required.
Repeat this sequence
until the entire SCID
number is entered.
9) Once the entire SCID
value is entered, press
F1
10) The next RF setup
parameter is “ChnL”
(Channel). Press
F1
to start
the number entry process.
11) The current RF channel
number is displayed.
If the offered RF Channel value is
correct, push
F1
and jump to step 14.
SCROLL
F2
ENTER/SELECT
F1
ENTER/SELECT
F1
ENTER/SELECT
F1
ENTER/SELECT
F1
F2
F2
SCROLL
F2
ENTER/SELECT
F1
ENTER/SELECT
F1
Press Simultaneously
F1
F2
Communication Setup
43
Figure 6-7 RF Setup Procedure