12
MSI-7300 Operator’s Manual
2.0 Operation
2.1 Power
To turn on the Power
1. Press
POWER
.
• The LCD will show all segments for a display test.
• The software version number will display.
The
Dyna-Link 2
is ready for use.
2.2 Zero
Takes out small deviations in zero when the
Dyna-Link 2
is unloaded. See Section 3.6
for zeroing (Taring) package or pallet weights.
Note
Note
The tension reading must be stable within the motion window for the
zero function to work.
1. Press
ZERO
.
The display reads 0 (or 0.0 or 0.00, etc).
The backup memory stores the zero reading, and can restore it even if
power fails.
Zero - Rules for Use:
• Works in
GROSS
mode or
NET
mode. Zeroing while in
NET
mode will zero
the gross tension causing the display to show the negative tare value.
• The unit must be stable within the motion window, it will not zero until the
stable annunciator is on.
• The unit will “remember” that it has a zero request for two seconds. If motion
clears in that time, it will zero.
• The unit will accept a zero setting over the full range of the Dyna-Link. Zero
settings above 4% of full Dyna-Link will subtract from the overall capacity.
For example, if you zero out 100 lb on a 1000 lb Dyna-Link, the overall
capacity will reduce to 900 lb plus the allowed over-range amount.
Содержание Dyna-Link 2
Страница 2: ...MSI 7300 Dyna Link 2 Tension Dynamometer Operator s Manual PN 152160 Rev C...
Страница 3: ......
Страница 58: ...Appendix 53 Notes...
Страница 59: ...54 MSI 7300 Operator s Manual Notes...
Страница 60: ......