5. Screw the new spare part (C) with
the internal hose with wrench size 14
into the housing. Then screw the
switching unit in place with wrench
size 16 and brace with wrench size 14.
6. Wrap the thread of the blue Tornador
hose with sealing tape and remove any
protruding ends of sealing tape with a
knife.
7. Lay the blue Tornador hose (A) over
the internal hose (C) and screw it into
the housing (B) with wrench size 10.
8. Cut off the protruding internal (C)
hose so that it is level with the blue
Tornador hose (A). Then twist open the
spout.