"OPERATION"
- Displays the operation status
“VOLTAGE”
- Displays the configured by a user the voltage with the help of the encoder that will
be applied to the solenoid pull in and holding windings during the test.
"CURRENT"
- Displays the current consumed by the solenoid pull in and holding windings
"PULL"
- pull in winding
"HOLD"
- holding winding
"DROPOUT"
- Displays the voltage drop directly on the
power contacts of the solenoid *
"SYSTEM SETTINGS"
- Button to enter the "system parameters" menu.
“SOLENOID PARAMETERS”
- Button to enter the “solenoid parameters” menu
“APPLY LAST RESULTS”
– setting the parameters of the tested solenoid as reference, to compare
them with the results of the subsequent checks.
3.3.2 System parameters menu
Pic. 3 SYSTEM SETTINGS
* When measuring plates of power clamps are disconnected, the value changes randomly due to
interference, which is the normal things.