background image

GENERAL DESCRIPTION

The Ultravue APR Respirator is an air purifying respirator
intended for use in atmospheres which are not immediate-
ly dangerous to life or health (non-IDLH). This respirator is
intended for applications which may require the user to
enter or exit a hazardous area, or work within the area for
a limited time.

Inhaled air is drawn through the canister/cartridge(s),
which contains adsorbents and a filter that removes or
neutralizes specific contaminations. Exhaled air leaves the
facepiece through the exhalation valve.

It is important that the user becomes familiar with the
application and operation of the Ultravue APR Respirator
and ensures that it fits properly before use.

When properly fitted to the user, the Ultravue full face-
piece with nosecup and head harness, combined with the
appropriate canister/cartridge(s), becomes a complete
respiratory protective device.

The respirator consists of the following subassemblies:

full facepiece (with optional nosecup)

filter canister/cartridge(s)

Facepieces are available in the following sizes and head
harness configurations:

P/N

Description

471218

Small, Hycar

457126

Medium, Hycar

471230

Large, Hycar

480251

Small, Silicone

480247

Medium, Silicone

480255

Large, Silicone

Facepiece size is identified on the front of the facepiece
behind the center of the lens and in front of the nosecup.

RESPIRATOR USE LIMITATIONS

The wearer must comply with the following MSA respira-
tor use limitations:
A. MAXIMUM USE CONCENTRATION – Do not exceed

any of the following:

1. Routine Use –

a. 50 times the exposure limit for the contaminants

present if using a quantitative fit test method. Using
a qualitative fit test may reduce the maximum use
concentration. See the Respirator Fit Test section.

b. Immediately Dangerous to Life or Health (IDLH) con-

centration for any contaminant present.

5

TAL 804 (L) Rev. 5 - 10068239

Canister for Chin-Type Gas Masks

Maximum Escape

Part No.

MSA Canister

Purifying

Approval

Conditions

Gas/Vapors

Identification

Protection Code

% Volume

PPM

815994

GMA-C-N95

OV

TC-14G-0197

0.50%

5000

Organic Vapors*

815996

GMC-C-N95

OV/AG

TC-14G-0196

0.50%

5000

Organic Vapors and Acid
Gases*

816051

GMF-C-N95

AG/FM

TC-14G-0207

0.50%

5000

Acid Gases*

0.05%

500

Formaldehyde*

0.15%

1500

Phosphine*

815993

GMD-C-N95

AM

TC-14G-0198

0.50%

5000

Ammonia*

815995

GML-C-N95

CL2

TC-14G-0199

0.50%

5000

Chlorine*

915999

GMDL-C-N95

OV/CL2/AM

TC-14G-0200

0.50%

5000

Ammonia, Chlorine, and
Organic Vapors*

815998

GMR-I-P100

OV/I2

TC-14G-0204

0.50%

5000

Organic Vapors

816000

GMHF-C-P100

HF

TC-14G-0239

0.10%

1000

Hydrogen Fluoride

10059903

Phosphine/

PH/AM/CL

TC-14G-0274

0.50%

5000

Ammonia and Chlorine

Ammonia/Chlorine/

0.15%

1500

Phosphine

P100

10067469

Organic Vapor/

OV

TC-14G-0279

0.50%

5000

Organic Vapors

P100

10067491

Hydrogen

HF

TC-14G-0280

0.10%

1000

Hydrogen Fluoride

Fluoride/P100

10067470

Formaldehyde

FM/AG/CD/HS

TC-14G-0282

0.05%

500

Formaldehyde

Acid Gas/Chlorine

0.50%

5000

Acid Gases and Hydrogen

Dioxide/Escape

Sulfide

from Hydrogen

0.10%

1000

Chlorine Dioxide

Sulfide P100

2. Escape (for Gas Mask only) –

*Canister contains an N95-Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil.

Canister contains a P100-Particulate Filter (99.97 filter efficiency level) effective against all particulate aerosols.

Содержание Ultravue GME-P100

Страница 1: ...H Approval Information P N 10035719 P100 GME P100 P N 818206 Ultra Twin P N 817241 Gas Mask P N 818082 CS CN This manual must be carefully read and followed by all persons who have or will have the re...

Страница 2: ...o User s Instructions before donning LL This respirator contains filter or cartridge components that are not approved for protections in all configura tions Check the specific row in the NIOSH approva...

Страница 3: ...te or smell the contaminant d You experience nose or throat irritation e Instructed by responsible individuals 12 Use strictly according to the instructions labels and limitations pertaining to this d...

Страница 4: ...4 TAL 804 L Rev 5 10068239 NOTES...

Страница 5: ...es the exposure limit for the contaminants present if using a quantitative fit test method Using a qualitative fit test may reduce the maximum use concentration See the Respirator Fit Test section b I...

Страница 6: ...a mix ture of chlorine and mercury that are both present simultaneously but cannot be used if alternating between mercury contaminated atmospheres and chlorine contaminated atmospheres E TIME USE LIMI...

Страница 7: ...ned to ensure proper fit before using the respirator If other than facial seal leakage is detected the condition must be investigated and corrected before another test is made The facepiece must also...

Страница 8: ...8 TAL 804 L Rev 5 10068239 NOTES...

Страница 9: ...oring the canister outside the packaging Discard canister cartridge s after each use Replace the canister cartridge s after each use Follow the established canister cartridge s change out sched ules t...

Страница 10: ...he replacement cartridges from the storage bags and insert them into the threaded receptacles making sure the gaskets are in place in the recepta cles 6 Carefully hand tighten the cartridges to preven...

Страница 11: ...back of the head 4 Support the weight of the mask by holding the outlet valve assembly in the palm of the hand with the free hand adjust the facepiece securely to the face mak ing sure the chin and n...

Страница 12: ...t again 5 If this does not correct the leak the mask will not pro vide protection If the leakage is from the face seal a different size mask may provide a good seal If other than face seal leakage is...

Страница 13: ...must be per formed Disposal is to be performed as required by feder al state and or local laws PROCEDURE FOR REMOVING THE RESPIRATOR 1 To remove the facepiece insert your thumbs under each of the har...

Страница 14: ...14 TAL 804 L Rev 5 10068239 NOTES...

Страница 15: ...tions with the Confidence Plus Cleaning Solution b If the Confidence Plus Cleaning Solution is not used wash in a mild cleaning solution rinse thor oughly and submerge in a germicide solution for the...

Страница 16: ...16 TAL 804 L Rev 5 10068239 NOTES...

Страница 17: ...the white inhalation disc valve is attached to the spider gasket The disc must be free of cracks tears dirt and distortion 9 Set the gasket with inhalation valve disk aside in a clean location 10 Expo...

Страница 18: ...18 TAL 804 L Rev 5 10068239 NOTES...

Страница 19: ...sing the supplied cap plug component Remove the canister from the box and bag Locate the white block on the canister label Mark on the canister in the white block an expiration date of 1 year for form...

Страница 20: ...e with the plug side of the cap and plug component secured into position The respirator must be placed upright in the plastic case P N D2056734 DO NOT store the canister above 120 F Failure to fol low...

Страница 21: ...s the support assembly a rubber block and the spectacle frame Prescription lenses can be obtained locally or through MSA Adjusting the Spectacles 1 To move the spectacles closer to your face pull the...

Страница 22: ...ark cover is optional OTHER RESPIRATORY CONFIGURATIONS This respirator can be used in other configurations that stated in these User s Instructions Below is a list of these other configurations and th...

Страница 23: ...ULTRAVUE FACEPIECE 23 TAL 804 L Rev 5 10068239...

Страница 24: ...agent employee or representative of MSA may bind MSA to any affirmation representation or modification of the warranty concerning the goods sold under this con tract MSA makes no warranty concerning...

Отзывы: