INSPECTION
INSPECTION
(Before and After Each Use)
•
Inhalation valve disc
•
Exhalation valve disc
•
Harness straps
•
Lens
•
Canister/cartridge(s)
•
Facepiece blank
•
Accessories
INSPECTION PROCEDURES
1. Look for breaks or tears in the facepiece head-strap
material.
2. Make sure all straps, fasteners, and adjusters are in
place and not damaged.
3. Check the facepiece for dirt, cracks, tears, or holes.
4. Check the lens for cuts, scratches, or damage which
would impair vision. Check that the lens is secured in
the facepiece.
5. Look at the shape of the facepiece for distortion due
to improper storage.
6. Unthread the canister/cartridge(s) (if installed), and
check that the spider gasket, and inhalation valve are
installed and undamaged.
7. Grasp the spider gasket by the raised tab and pull it
gently out of the facepiece. The gasket must be free
of cracks, tears, dirt, and distortion. The gasket must
be soft and flexible.
8. Ensure the white inhalation disc valve is attached to
the spider gasket. The disc must be free of cracks,
tears, dirt, and distortion.
9. Set the gasket with inhalation valve disk aside in a
clean location.
10. Expose the exhalation valve by lifting the tab on the
bottom door of the component housing away from the
facepiece.
11. Lift the exhalation valve and inspect the seat and
valve.
12. Securely close the door of the component housing.
13. While holding the spider gasket in one hand, gently
stretch the inhalation valve disk onto the post in the
center of the spider gasket.
14. Install the spider gasket into the inlet port with the
white inhalation valve disk into the facepiece. Check
around the entire gasket to be sure the gasket lays flat
and that the groove in the gasket is entirely captured
by the component housing rim.
15. If any part is damaged or deteriorated, it must be
replaced. Store only undamaged respirators for further
use. When not in use, store the respirator in cool, dry,
and clean ambient air in the original clamshell packag-
ing. Keep new filters in their packing.
17
TAL 804 (L) Rev. 5 - 10068239
Содержание Ultravue GME-P100
Страница 4: ...4 TAL 804 L Rev 5 10068239 NOTES...
Страница 8: ...8 TAL 804 L Rev 5 10068239 NOTES...
Страница 14: ...14 TAL 804 L Rev 5 10068239 NOTES...
Страница 16: ...16 TAL 804 L Rev 5 10068239 NOTES...
Страница 18: ...18 TAL 804 L Rev 5 10068239 NOTES...
Страница 23: ...ULTRAVUE FACEPIECE 23 TAL 804 L Rev 5 10068239...