PREPARING THE RESPIRATOR FOR USE
2. Remove the adapter from bag and position in the inlet
of the facepiece.
3. Hand-tighten the plastic nut on the adapter making
sure the mail portion of the adapter seals agains the
spider gasket in the facepiece inlet.
4. If using the Duo-Twin plug as described in the follow-
ing section.
5. Remove the replacement cartridges from the storage
bags and insert them into the threaded receptacles
making sure the gaskets are in place in the recepta-
cles.
6. Carefully hand-tighten the cartridges to prevent dam-
age to threads. To ensure a good seal against the gas-
kets, tighten each cartridge by gripping as much of
the circumference of the receptacle as possible and
then slowly turn the cartridge until tight.
7. If applicable, place a new filter in each filter cover.
Never load filters into the receptacles.
10
TAL 804 (L) Rev. 5 - 10068239