ACCESSORIES
The facepiece may be equipped with the fol-
lowing accessories:
1. ESP
®
Communication System
2. Lens (tinted), in small, medium, or large
3. Spectacle Kit
4. Hood
Refer to the NIOSH Approval Matrix for a
complete list of Approved Accessories. If
you must wear corrective eyewear, install
an approved spectacle kit, listed on the
NIOSH approval matrix insert.
Know the contaminant(s) in the environ-
ment before entering. Always check that
the filter canister/cartridge(s) is appropri-
ate for use in the environment. A filter
canister/cartridge(s) which is not
designed for the contaminant present
may not provide protection. Failure to fol-
low this warning can result in serious
personal injury or death.
Installing the Nosecup for Ultra Elite
Facepiece
1. Place the nosecup in the facepiece and
position it so its rubber ring faces toward
the plastic retainer ring.
2. Starting at the top,
stretch and push the rub-
ber ring of the nosecup
under the plastic retainer
ring of the speaking
diaphragm assembly.
3. Continue stretching the .
nosecup ring and work it into place.
4. For Ultra Elite Facepieces only, stretch
the oval opening in the nosecup around
the lip on its component housing.
Spectacle Kit
Spectacle kits are available for the Ultra
Elite (P/N 804638). The kit includes the sup-
port assembly, a rubber block, and the spec-
tacle frame. Prescription lenses can be
obtained locally or through MSA.
Adjusting the Spectacles
1. To move the spectacles closer to your
face, pull the frame prongs out of the
rubber block.
2. To move the spectacles farther from your
face, push the frame prongs into the rub-
ber block.
3. To move the specta-
cles up or down, slide
the rubber block up or
down on the support
arms.
Gas Mask and Belt-Mounted Applications
Only
Attaching the Gas Mask Chin Canister to
the Belt
This conversion kit consists of:
Installation Instructions
Note:
Before installation, check breathing tube
for cracks or tears. If a crack or tear is present,
replace the breathing tube before use.
1. Attach the male thread end of the
breathing tube securely to the facepiece
component housing.
2. Slide the belt clip over the neck of the
canister.
3. Securely fasten the female end of the
breathing tube to the male end of the
canister.
4. Attach the belt around the waist and
attach the belt clip to the belt.
ACCESSORIES
LVG 322 (L)
Rev. 1
3
- 10050775
29
Qty
Item
Part Number
1
Belt Clip
10068195
1
Breathing Tube
10068129
1
Belt
473902, 9961,
492827
1
Spark Cover
10068152